A computational study on mixed convection in a porous media filled and partially heated lid-driven cavity with an open side

dc.contributor.authorAbu-Hamdeh, Nidal H.
dc.contributor.authorÖztop, Hakan Fehmi
dc.contributor.authorAlnefaie, Khalid A.
dc.date.accessioned2026-08-12T17:50:23Z
dc.date.issued2020
dc.departmentFırat Üniversitesi
dc.description.abstractApplications of mixed convection due to lid-driven cavities can be found in different engineering technologies. A computational study was conducted to explore the effects of different parameters on mixed convection in a porous media filled lid-driven cavity with one side opening in the presence of heat generation. The cavity has a flush mounted heater on its bottom wall. The governing equations were solved by developing a computer code by using finite volume technique for different parameters as length of heater (1/5, 2/5, 4/5), Richardson number (0.1, 1, 10) and Darcy number (0.1, 0.01, 0.001). It is found that heat transfer and flow field inside the cavity is so complex due to moving lid, open side wall and heater. Heat transfer increases with increasing of Grashof numbers, heater length and decreased with Darcy numbers. (C) 2020 The Authors. Published by Elsevier B.V. on behalf of Faculty of Engineering, Alexandria University.
dc.description.sponsorshipDeanship of Scientific Research (DSR), King Abdulaziz University, Jeddah, Saudi Arabia [KEP-4-135-38]; DSR
dc.description.sponsorshipThis project was funded by the Deanship of Scientific Research (DSR), King Abdulaziz University, Jeddah, Saudi Arabia under grant no. (KEP-4-135-38). The authors, therefore, acknowledge with thanks DSR technical and financial support.
dc.identifier.doi10.1016/j.aej.2020.04.039
dc.identifier.endpage1750
dc.identifier.issn1110-0168
dc.identifier.issn2090-2670
dc.identifier.issue3
dc.identifier.orcid0000-0003-0639-1359
dc.identifier.scopus2-s2.0-85086049853
dc.identifier.scopusqualityQ1
dc.identifier.startpage1735
dc.identifier.urihttps://doi.org/10.1016/j.aej.2020.04.039
dc.identifier.urihttps://hdl.handle.net/11508/62199
dc.identifier.volume59
dc.identifier.wosWOS:000542588900020
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofAlexandria Engineering Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectLid-driven cavity
dc.subjectPorous
dc.subjectOpen cavity
dc.subjectPartial heating
dc.subjectFinite volume technique
dc.titleA computational study on mixed convection in a porous media filled and partially heated lid-driven cavity with an open side
dc.typeArticle

Dosyalar