Machine learning-assisted performance prediction for dual PV-TEG systems with a triangular-elliptical cooling channel

dc.contributor.authorSelimefendigil, Fatih
dc.contributor.authorErtam, Fatih
dc.contributor.authorÖztop, Hakan Fehmi
dc.date.accessioned2026-08-12T17:28:32Z
dc.date.issued2026
dc.departmentFırat Üniversitesi
dc.description.abstractOptimized thermal management of PV (photovoltaic) units is key to improving their energy conversion efficiency and maintaining stable operation. This study presents a novel lightweight cooling system featuring a triangular cavity with an inner elliptical section, integrated with two thermoelectric generator (TEG) units, to improve the performance of dual PV modules. Using finite element method, the channel's cooling performance is investigated by varying the flow Reynolds number (Re from 100 to 500), the height of the inner elliptical section (h from 0.01H to 0.3H), the radius of the elliptical curvature (r from 0.01H to 0.2H), and the width of the elliptical gap (l from 0.2H to 0.5H). Machine learning-based regression is used to predict cooling performance of the triangular channel with inner elliptic part. The top-performing model is then combined with the PV-TEG unit to forecast the performance of the dual PV-TEG system. The most pronounced enhancement in cooling is observed when varying the flow Reynolds number, followed by changes in the height and radius of the elliptical curvature. The width of the inner elliptical section has the minimal effect on cooling performance. The optimal cooling performance is obtained with geometric parameters (h, r, l) = (0.3H, 0.2H, 0.5H), whereas the absence of the inner elliptical section leads to the poorest cooling. With the best cooling configuration, PV-cell temperatures decrease by 7.4 degrees C for PV-r and 3.1 degrees C for PV-l compared to the worst-case. The temperature difference between PV-r and PV-l is 4.8 degrees C under the worst cooling conditions, but reduces to 0.5 degrees C in the optimal scenario. Feature importance analysis showed that the Reynolds number has the dominant effect on heat transfer, explaining 57%-78% of the observed variance, whereas geometric parameters have a relatively minor impact. Cross-validation further confirmed that support vector regression (SVR) provides the most consistent generalization performance, highlighting its reliability for practical applications. The optimal configuration reduces the channel volume by 35.6% compared to a design without the inner elliptical section.
dc.identifier.doi10.1016/j.ijheatfluidflow.2026.110332
dc.identifier.issn0142-727X
dc.identifier.issn1879-2278
dc.identifier.scopus2-s2.0-105030886630
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1016/j.ijheatfluidflow.2026.110332
dc.identifier.urihttps://hdl.handle.net/11508/55342
dc.identifier.volume119
dc.identifier.wosWOS:001705377000001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Science Inc
dc.relation.ispartofInternational Journal of Heat and Fluid Flow
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectTriangular complex channel
dc.subjectMachine learning
dc.subjectDouble PV-TEG units
dc.subjectCFD
dc.titleMachine learning-assisted performance prediction for dual PV-TEG systems with a triangular-elliptical cooling channel
dc.typeArticle

Dosyalar