Double-balloon tamponade in the management of postpartum hemorrhage: a case series

dc.contributor.authorKavak, Salih Burin
dc.contributor.authorKavak, Ebru Celik
dc.contributor.authorDemirel, Ismail
dc.contributor.authorIlhan, Rasit
dc.date.accessioned2026-08-12T17:32:17Z
dc.date.issued2014
dc.departmentFırat Üniversitesi
dc.description.abstractTo show the efficacy of double-balloon cervical ripening catheter in the management of postpartum hemorrhage originating from the lower segment of the uterus or the upper parts of the vagina. Methods: Patients with intractable bleeding from the lower segment of the uterus and the upper parts of the vagina after Cesarean or vaginal deliveries were treated by double-balloon cervical ripening catheter. Results: Double-balloon catheter was used in seven patients, and it was properly placed in all of them. No other intervention was needed to control bleeding. Two patients were delivered vaginally, and five patients were delivered by Cesarean section. Length of hospitalization was longer in the vaginal delivery patients (average hospitalization was 12 days in the vaginal delivery patients and 5 days in the Cesarean section patients). The need for blood and blood products transfusion (average of blood and blood products transfusion was 30 U in the vaginal delivery patients and 6 U in the Cesarean patients) was also higher in the vaginal delivery patients. Conclusion: Although double-balloon cervical ripening catheter is designed for the induction of labor, it can successfully control intractable bleedings from the lower segment of the uterus and the upper parts of the vagina. This procedure can save patients from undergoing more morbid procedures.
dc.identifier.doi10.2147/TCRM.S62574
dc.identifier.endpage620
dc.identifier.issn1178-203X
dc.identifier.pmid25120367
dc.identifier.scopus2-s2.0-84905686307
dc.identifier.scopusqualityQ1
dc.identifier.startpage615
dc.identifier.urihttps://doi.org/10.2147/TCRM.S62574
dc.identifier.urihttps://hdl.handle.net/11508/56574
dc.identifier.volume10
dc.identifier.wosWOS:000340178300003
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherDove Medical Press Ltd
dc.relation.ispartofTherapeutics and Clinical Risk Management
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectcesarean section
dc.subjectdouble-balloon catheter
dc.subjectpostpartum hemorrhage
dc.subjectvaginal delivery
dc.titleDouble-balloon tamponade in the management of postpartum hemorrhage: a case series
dc.typeArticle

Dosyalar