A performance comparison between a horizontal source and a vertical source heat pump systems for a greenhouse heating in the mild climate Elazig, Turkey
| dc.contributor.author | Benli, Huseyin | |
| dc.date.accessioned | 2026-08-12T17:46:41Z | |
| dc.date.issued | 2013 | |
| dc.department | Fırat Üniversitesi | |
| dc.description.abstract | The investigation presented in this article is aimed at demonstrating the technical and design feasibility of using ground-source heat pump systems in the mild climate applications for greenhouse heating, where heating requirements are dominant. An experimental comparison between a horizontal ground-source heat pump system and a vertical ground-source heat pump system was shown by focusing on the heating performance. For this purpose, an experimental set-up was constructed. The heating system mainly consists of two different ground heat exchangers, a heat pump, measuring units and a heating space of a model-sized glass greenhouse with 30 m(2) located in the greenhouse location. The heating coefficient of performances of the two ground-source heat pumps (COPHP,H-V) and the overall system (COPsys,H-V) were obtained to be in the range of 3.1-3.6 for HGSHP and 3.2-3.8 for VGSHP and 2.7-3.3 for HGSHP and 2.9-3.5 for VGSHP, respectively. Although significant savings are possible with these heating systems, a substantial investment in equipment and facilities may be required. The experimental results were obtained from November to April in heating seasons of 2007-2008. The results showed that the utilization of the ground-source heat pump is suitable for greenhouse heating in this district. (C) 2012 Elsevier Ltd. All rights reserved. | |
| dc.identifier.doi | 10.1016/j.applthermaleng.2012.06.005 | |
| dc.identifier.endpage | 206 | |
| dc.identifier.issn | 1359-4311 | |
| dc.identifier.issue | 1 | |
| dc.identifier.orcid | 0000-0002-4057-8750 | |
| dc.identifier.scopus | 2-s2.0-84866495178 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 197 | |
| dc.identifier.uri | https://doi.org/10.1016/j.applthermaleng.2012.06.005 | |
| dc.identifier.uri | https://hdl.handle.net/11508/61168 | |
| dc.identifier.volume | 50 | |
| dc.identifier.wos | WOS:000314191100023 | |
| dc.identifier.wosquality | Q1 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Pergamon-Elsevier Science Ltd | |
| dc.relation.ispartof | Applied Thermal Engineering | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WoS_20260511 | |
| dc.subject | Ground-source heat pump (GSHP) | |
| dc.subject | Greenhouse | |
| dc.subject | Elazig | |
| dc.subject | Renewable energy | |
| dc.title | A performance comparison between a horizontal source and a vertical source heat pump systems for a greenhouse heating in the mild climate Elazig, Turkey | |
| dc.type | Article |