Measurement of intraocular pressure in clinically normal Turkish Shepherd Dogs with the rebound tonometer (TonoVet®) and the applanation tonometer (Tono-Pen Vet®)

dc.contributor.authorKulualp, Kadri
dc.contributor.authorYurdakul, Ibrahim
dc.contributor.authorErol, Hanifi
dc.contributor.authorAtalan, Gultekin
dc.contributor.authorKilic, Servet
dc.date.accessioned2026-08-12T17:05:08Z
dc.date.issued2018
dc.departmentFırat Üniversitesi
dc.description.abstractThe current study was undertaken to establish reference values of intraocular pressure in clinically normal Turkish Shepherd Dogs with the rebound tonometer (TonoVet (R)) and the applanation tonometer (Tono-Pen Vet (R)). Twenty-eight dogs (14 male and 14 female, aged 9 months-9 years, 56 eyes) were used in this study. All animals were healthy and showed no abnormalities in ophthalmic examinations, which consisted of the Schirmer tear test, slit lamp bio-microscopy, and fluorescein staining. The animals were restrained manually without using systemic anesthetics or tranquilizers. IOP was measured in both eyes with a TonoVet (R) and a Tono-Pen Vet (R). In normal dogs, the mean IOP values for all eyes were 17.63 +/- 3.34 mmHg according to the TonoVet (R) and 14.95 +/- 2.92 mmHg according to the Tono-Pen Vet (R). There was no effect of sex, age, or eye side (right vs. left) on the results obtained with either the TonoVet (R) or the Tono-Pen Vet (R). The mean IOP obtained with the rebound tonometer was 2-3 mmHg higher than that measured with the applanation tonometer. The reference data obtained in the present study may assist in diagnostic testing for ophthalmic diseases in Turkish Shepherd Dogs and may promote further studies in this area.
dc.identifier.doi10.21521/mw.6024
dc.identifier.endpage573
dc.identifier.issn0025-8628
dc.identifier.issue9
dc.identifier.scopus2-s2.0-85054822766
dc.identifier.scopusqualityQ4
dc.identifier.startpage568
dc.identifier.urihttps://doi.org/10.21521/mw.6024
dc.identifier.urihttps://hdl.handle.net/11508/48997
dc.identifier.volume74
dc.identifier.wosWOS:000442755200003
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPolish Soc Veterinary Sciences Editorial Office
dc.relation.ispartofMedycyna Weterynaryjna-Veterinary Medicine-Science and Practice
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectapplanation tonometry
dc.subjectrebound tonometry
dc.subjectdog
dc.subjecteye
dc.subjectintraocular pressure
dc.titleMeasurement of intraocular pressure in clinically normal Turkish Shepherd Dogs with the rebound tonometer (TonoVet®) and the applanation tonometer (Tono-Pen Vet®)
dc.typeArticle

Dosyalar