Evaluation of maxillary sinus septa: a retrospective clinical study with cone beam computerized tomography (CBCT)

dc.contributor.authorYildirim, T. Talo
dc.contributor.authorGuncu, G. -N.
dc.contributor.authorColak, M.
dc.contributor.authorNares, S.
dc.contributor.authorTozum, T. -F.
dc.date.accessioned2026-08-12T16:41:19Z
dc.date.issued2017
dc.departmentFırat Üniversitesi
dc.description.abstractOBJECTIVE: To determine the prevalence, height, location, orientation, and type of maxillary sinus septa in atrophic, non-atrophic, and partially atrophic maxillary segments using cone beam computerized tomography (CBCT). PATIENTS AND METHODS: This cross-sectional study was conducted on a retrospective evaluation of CBCT images of 1000 maxillary sinus with 500 subjects from December 2009 to December 2012. The differences among gender, left and right side of maxillary sinus, type of crest and feature of septa were statistically analyzed. RESULTS: A total of 297 septa was recorded in 1000 maxillary sinuses (29.7%) with a mean height was 4.62 +/- 2.50 mm. Forty-four (8.7%) septa were located in the anterior area, 123 (24.5%) in the middle area, and 131 (26.4%) in the posterior area. Seventy maxillary sinus septa (26.1%) were observed with a mediolateral type orientation. There were no significant differences between all features of maxillary sinus septa and gender or type of crest. The only significant association identified was between type of crest and type of septa. CONCLUSIONS: The maxillary sinus septa exhibited variable characteristics according to orientation and type of crest. CBCT analysis is very important and should be performed before maxillary sinus surgery to prevent possible complications.
dc.identifier.endpage5314
dc.identifier.issn1128-3602
dc.identifier.issue23
dc.identifier.orcid0000-0002-7485-7272
dc.identifier.orcid0000-0001-8456-5583
dc.identifier.orcid0000-0001-9491-6447
dc.identifier.pmid29243773
dc.identifier.scopus2-s2.0-85042148450
dc.identifier.scopusqualityN/A
dc.identifier.startpage5306
dc.identifier.urihttps://hdl.handle.net/11508/45776
dc.identifier.volume21
dc.identifier.wosWOS:000419143200003
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherVerduci Publisher
dc.relation.ispartofEuropean Review for Medical and Pharmacological Sciences
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectTomography
dc.subjectSinus
dc.subjectAnatomy
dc.subjectRadiology
dc.subjectHumans
dc.titleEvaluation of maxillary sinus septa: a retrospective clinical study with cone beam computerized tomography (CBCT)
dc.typeArticle

Dosyalar