Effects of Local and Systemic Zoledronic Acid Application on Titanium Implant Osseointegration: An Experimental Study Conducted on Two Surface Types

dc.contributor.authorDundar, Serkan
dc.contributor.authorYaman, Ferhan
dc.contributor.authorGecor, Orhan
dc.contributor.authorCakmak, Omer
dc.contributor.authorKirtay, Mustafa
dc.contributor.authorYildirim, Tuba Talo
dc.contributor.authorBenlidayi, Mehmet Emre
dc.date.accessioned2026-08-12T17:17:12Z
dc.date.issued2017
dc.departmentFırat Üniversitesi
dc.description.abstractThe aim of this study was to evaluate the effects of local and systemic zoledronic acid (ZA) applications on titaniumoksit ceramic blasted (TiO-CB)- and sandblasted large acid-grit (SLA)-surfaced titanium implant osseointegration. Twelve New Zealand White rabbits were used in the study, divided into 6 groups: the TiO-CB (TiO-CB-CNT) (n = 2) and SLA (SLA-CNT) (n = 2) control groups in which TiO-CB- and SLA-surfaced titanium implants were surgically inserted into rabbit tibias but no treatment was applied; the TiO-CB (TiO-CB-LZA) (n = 2) and SLA (SLA-LZA) (n = 2) local ZA groups in which 1 mL of normal saline solution containing 2 mg of ZA was injected into sockets and after this the implants were integrated; and the TiO-CB (TiO-CB-SZA) (n = 2) and SLA (SLA-SZA) (n = 2) systemic ZA groups in which a single infusion of 0.1 mg/kg of ZA was administered during surgical implant insertion. Following a period of osseointegration, bone implant contact (BIC) was recorded as a proportion of the total implant surface length in direct contact with the bone. Results of this study indicate that BIC was greater in the systemic ZA application groups than in the local ZA application groups, and BIC was greater in the local ZA groups than in the controls. Statistically significant differences in BIC were not detected between the TiO-CB- and SLA-surfaced implants in all the groups. Furthermore, this study did not reveal significant differences between the 2 types of surfaces due to similar average roughness values. Overall, systemic ZA application was found to be more effective in increasing BIC than local ZA application based on the results obtained by testing 2 implant surfaces.
dc.description.sponsorshipFirat University Scientific Research Project Foundation Department [DHF.15.01]
dc.description.sponsorshipThis study was supported by Firat University Scientific Research Project Foundation Department with the project number DHF.15.01.
dc.identifier.doi10.1097/SCS.0000000000003568
dc.identifier.endpage938
dc.identifier.issn1049-2275
dc.identifier.issn1536-3732
dc.identifier.issue4
dc.identifier.orcid0000-0003-2568-7470
dc.identifier.pmid28230589
dc.identifier.scopus2-s2.0-85013631401
dc.identifier.scopusqualityQ3
dc.identifier.startpage935
dc.identifier.urihttps://doi.org/10.1097/SCS.0000000000003568
dc.identifier.urihttps://hdl.handle.net/11508/52558
dc.identifier.volume28
dc.identifier.wosWOS:000402750600058
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherLippincott Williams & Wilkins
dc.relation.ispartofJournal of Craniofacial Surgery
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectBone implant connection
dc.subjectosseointegration
dc.subjectrabbit tibiae
dc.subjectsurface roughing
dc.subjectzoledronic acid
dc.titleEffects of Local and Systemic Zoledronic Acid Application on Titanium Implant Osseointegration: An Experimental Study Conducted on Two Surface Types
dc.typeArticle

Dosyalar