dc.description.abstractIntroduction: The aim of this study was to make a quantitative comparison of the cytotoxic potentials of four different polymerised and unpolymerised self-etching adhesives which were newly used clinically. Materials and Methods: Cytotoxic effects of both polymerised and unpolymerised forms of all test adhesives were evaluated against L929 cell line using the MTT test. The activity for unpolymerised adhesives was assessed in different doses and incubation times manner. On the other hand, cytotoxicity of the polymerised adhesives prepared at different extraction times were evaluated as dependent on incubation times. Two-Way Variance Analysis and Bonferroni post-test was used for statistical evaluation. Results: There were statistically significant differences between the groups (p < 0.05). In general, it was shown that unpolymerised and polymerised forms of each of the test compounds exhibited a time-dependent cytotoxic effect. However, the effect on polymerised forms was found to be independent of the duration of the extraction, while the effect on the unpolymerised forms increased dose-dependently. It was also determined that the most cytotoxic material in the unpolymerised form was Dentsply and in the polymerised form was Tokuyama. Conclusions: Dentsply should be preferred over Tokuyama to be able to provide clinically long-lasting restorations.
dc.identifier.doi10.3290/j.ohpd.a43940
dc.identifier.endpage51
dc.identifier.issn1602-1622
dc.identifier.issn1757-9996
dc.identifier.issue1
dc.identifier.orcid0000-0001-8883-8307
dc.identifier.pmid32051970
dc.identifier.scopus2-s2.0-85079336179
dc.identifier.scopusqualityQ1
dc.identifier.startpage43
dc.identifier.urihttps://doi.org/10.3290/j.ohpd.a43940
dc.identifier.urihttps://hdl.handle.net/11508/53015
dc.identifier.volume18
dc.identifier.wosWOS:000514443000007
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherQuintessence Publishing Co Inc
dc.relation.ispartofOral Health & Preventive Dentistry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectadhesive materials
dc.subjectcytotoxicity
dc.subjectpolymerisation
dc.subjectMTT test
dc.titleComparison of Cytotoxicity of Four Different Adhesive Materials Before and After Polymerisation
dc.typeArticle

Dosyalar