Measuring the resistance of different substructure materials by sticking them to dentine with two different resin cements in vitro

dc.contributor.authorEratilla, V.
dc.contributor.authorYildiz, A. D.
dc.contributor.authorGuven, S.
dc.contributor.authorEratilla, E. A.
dc.contributor.authorKaraman, T.
dc.contributor.authorAguloglu, S.
dc.contributor.authorSumer, E.
dc.date.accessioned2026-08-12T17:17:03Z
dc.date.issued2016
dc.departmentFırat Üniversitesi
dc.description.abstractIntroduction: The resistance of three different substructure materials - metal (Cr-Co), zirconium (Zr), and ceramics (IPS Empress II) - was measured by sticking them to dentine with two different resin cements, a dual-cure resin cement (Panavia F 2.0 Light) and a self-adhesive resin cement (BisCem). Materials and Methods: In an in vitro study, 72 central upper front teeth were selected with no decay or apparent breakage and with complete development, removed for periodontal reasons. Labial and incisal surfaces of all teeth were prepared. Molds were obtained to prepare metal (Co-Cr), Zr, and ceramic (IPS Empress II) blocks for use in the study. The compressive strengths of the obtained material infrastructures were examined after thermal cycle processing by performing cementation to the teeth with two different cements. The data obtained were analyzed statistically. The Mann-Whitney U-test was used for comparisons of the groups with two options, and Kruskal-Wallis variance analysis was used to compare more than two groups. P < 0.05 were considered statistically significant. Results: While the highest result between samples was 117.86 +/- 47.94 N in the dual-cure (Panavia) -ceramic group, the lowest value was observed at 6.53 +/- 3.12 N in the self-adhesive (BisCem) -metal group. There was a significant difference between dual-cure (Panavia) and self-adhesive (BisCem) groups. Conclusion: In this study, we measured the bond strength; our most durable resistance groups were found to be, in order, Panavia-ceramics >Panavia-metal >Panavia-Zr >self-adhesive-ceramics >self-adhesive-Zr >and self-adhesive-metal.
dc.description.sponsorshipDUAPK-Dicle University Research Project Council (DUBAP) [11-DH-65]
dc.description.sponsorshipThis study was funded by a grant from DUAPK-Dicle University Research Project Council (DUBAP) -11-DH-65.
dc.identifier.doi10.4103/1119-3077.164339
dc.identifier.endpage736
dc.identifier.issn1119-3077
dc.identifier.issue6
dc.identifier.orcid0000-0002-3511-5612
dc.identifier.pmid27811443
dc.identifier.scopus2-s2.0-84996504371
dc.identifier.scopusqualityQ2
dc.identifier.startpage730
dc.identifier.urihttps://doi.org/10.4103/1119-3077.164339
dc.identifier.urihttps://hdl.handle.net/11508/52526
dc.identifier.volume19
dc.identifier.wosWOS:000391532500008
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherMedknow Publications & Media Pvt Ltd
dc.relation.ispartofNigerian Journal of Clinical Practice
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectAdhesive system
dc.subjectbond strength
dc.subjectthermal cycle
dc.subjectzirconium
dc.titleMeasuring the resistance of different substructure materials by sticking them to dentine with two different resin cements in vitro
dc.typeArticle

Dosyalar