QT dispersion in carbon monoxide poisoning

dc.contributor.authorAtescelik, M.
dc.contributor.authorBozdemir, M. N.
dc.contributor.authorYildiz, M.
dc.contributor.authorGurbuz, S.
dc.contributor.authorAyranci, M.
dc.contributor.authorGoktekin, M. C.
dc.contributor.authorEken, C.
dc.date.accessioned2026-08-12T16:35:54Z
dc.date.issued2012
dc.departmentFırat Üniversitesi
dc.description.abstractBackground: Carbon monoxide (CO) poisoning are serious health problems, and effect of reducing the blood's oxygen carrying capacity. Deaths due to CO poisoning are mostly related to myocardial injury and central nervous system pathologies. Aim: The objective of this study was to determine the relationship between carbon monoxide intoxication, QT dispersion, and cardiac markers. Materials and Methods: Patients with possible CO intoxication symptoms were evaluated to be eligible for the study. Patients' demographic data, carboxyhemoglobin levels, cardiac markers and QT interval measurements were recorded to the study form. Results: A total of 127 patients (79 CO intoxicated and 48 controls) were included into the study with a mean age of 38.6 +/- 14.1 years and 62.2% of them were female. Average levels of patient's carboxyhemoglobin were 21.3 +/- 9. OT dispersion (39.0 +/- 10.8 vs 24.4 +/- 6.2; p < 0,001) and corrected QT dispersion (46.2 +/- 14.7 vs 25.3 +/- 6.2; p < 0.001) were longer than the control group. Both QT dispersion (39.0 I 10.8 vs 23.6 +/- 7.0; p < 0.001) or corrected QT dispersion (46.2 +/- 14.7 vs 27.1 +/- 8.7; p < 0.001) were also decreased after one week later from the admission. Conclusion: Carbon monoxide intoxication is related to increased OT dispersion. Emergency physicians should measure QT dispersion in CO intoxicated patients in order to predict the electrical instability in myocardium and future adverse events.
dc.identifier.endpage29
dc.identifier.issn1128-3602
dc.identifier.orcid0009-0004-4441-6056
dc.identifier.orcid0000-0002-2743-5608
dc.identifier.pmid22582480
dc.identifier.scopus2-s2.0-84860182574
dc.identifier.scopusqualityN/A
dc.identifier.startpage25
dc.identifier.urihttps://hdl.handle.net/11508/45069
dc.identifier.volume16
dc.identifier.wosWOS:000302849200006
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherVerduci Publisher
dc.relation.ispartofEuropean Review for Medical and Pharmacological Sciences
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectCarbon monoxide poisoning
dc.subjectQT dispersion
dc.subjectCardiac marker
dc.subjectEmergency Department
dc.titleQT dispersion in carbon monoxide poisoning