ÇOKLU TETRASİKLİN GRUBU KARIŞIMININ HİDROJEN VE OKSİJENE DAYALI MEMBRAN BİYOFİLM REAKTÖRLERİNDE GİDERİMİ

dc.contributor.advisorHASAR, HALİL
dc.contributor.authorYILMAZ, MERİÇ
dc.date.accessioned2019-08-13T20:45:28Z
dc.date.available2019-08-13T20:45:28Z
dc.date.issued2016
dc.departmentFÜ, Fen Bilimleri Enstitüsü, Çevre Teknolojileri Anabilim Dalı
dc.description.abstractTetrasiklin antibiyotikler (TCs) yaygın olarak insan tedavisi, hayvan tedavisi ve tarımda kullanılan geniş spektrumlu antimikrobiyal bileşiklerdir. Bu çalışmada hem H2'ye hem de O2'ye dayalı MBfR'larda eş zamanlı tetrasiklin, oksitetrasiklin, klortetrasiklin ve azotlu bileşiklerin giderimi çalışılmıştır. Hidrojene dayalı MBfR'da eş zamanlı olarak TC, OTC, CTC ve NO-3 giderimi çalışılırken, oksijene dayalı MBfR' de eş zamanlı olarak TC, OTC, CTC ve NH4 giderimi çalışılmıştır. Reaktörler 4 psi gaz basıncında ve 1-10 saat arasında değişen HRT' lerde işletilmiştir. Ayrıca çalışma sonuçlarına göre antibiyotik giderim verimleri, akı değerleri, hidrojen ve oksijen eşdeğer akıları hesaplanmıştır. Çalışma sonuçlarına göre H2-MBfR' de 10 saatlik HRT' de antibiyotik giderim oranları TC, OTC ve CTC için sırasıyla %93, % 91 ve % 99 olarak bulunmuştur. HRT 5 saate düşürüldüğünde giderim oranları sırasıyla % 66, % 69 ve % 91 'e düşmüştür ve HRT 1 saate alındığında antibiyotik giderim oranları belirgin düşüşler göstererek TC, OTC ve CTC için sırasıyla % 14, % 24, % 42 olarak hesaplanmıştır. Akı değerleri 10 saatlik hidrolik bekleme süresinde ortalama TC akısı 2,23 mg/m2.gün, ortalama OTC akısı 2,52 mg/m2.gün ve ortalama CTC akısı 2,87 mg/m2.gün olarak bulunmuştur. 1 saatlik HRT değerinde akı ve hidrojen eşdeğer akıları artış göstererek TC, OTC ve CTC ortalama akıları sırası ile 4,08 mg/m2.gün, 6,72 mg/m2.gün, 12,12 mg/m2.gün olarak bulunmuştur. O2-MBfR' de yapılan çalışma sonuçlarına göre ortalama TC giderim verimi %53, ortalama OTC giderim verimi %55, ortalama CTC giderim verimi % 71 olarak bulunmuştur. 5 saatlik hidrolik bekleme süresinde TC, OTC ve CTC ortalama giderim verimleri sırası ile % 21, % 37 ve % 45 olarak bulunmuştur. HRT 1 saate düşürüldüğünde giderim verimleri daha da kötüleşerek % 7, % 24 ve % 32 olarak bulunmuştur.10 saatlik hidrolik bekleme süresinde çoklu antibiyotik karışımındaki ortalama TC akısı 1,57 mg/m2.gün, ortalama OTC akısı 1,61 mg/m2.gün ve ortalama CTC akısı 2,08 mg/m2.gün bulunmuştur. 1 saatlik HRT değerinde ise TC, OTC ve CTC ortalama akıları sırası ile 1,92 mg/m2.gün, 7,08 mg/m2.gün, 9,36 mg/m2.gün olarak bulunmuştur. Anahtar kelimeler: Membrane Biofilm Reactor, Tetrasiklin, Oksitetrasikline, Klortetrasikline, Giderim Akısı, Eşdeğer Akı
dc.description.abstractRemoval of Multiple Tetracyclines Mixture in Hydrogen and Oxygen Based Membrane Biofilm Reactors Tetracycline antibiotics are broad spectrum antimicrobial compounds used commonly in human and animal treatment and agriculture. In this study, it has been studied the simultaneous removal of trible antibiotic mixture including tetracycline, oxytetracycline and chlortetracycline by using either H2- based MBfR or O2-based MBfR. While H2- MBfR was to remove NO3- and TCs mixture under denitrification conditions, O2-MBfR was to oxidize NH4+ and to degrade TCs mixture under nitrification conditions. Both MBfRs were opereted at gas pressure of 4 psi and HRTs between 1 and 10 hr. From experimental results, removal rates, contaminant' s fluxes and hydrogen and oxygen equivalent fluxes have been computed. After H2-MBfR achieved to the adaptation of microbial activities, while removal rates were obtained to be 93 % for TC, 91 % for OTC and 99 % for CTC at 10 hr, it decreased with decreasing of HRT, 66 % for TC, 69 % for OTC and 91 % for CTC at 5 hr. At HRT of 1 hr, antibiotic removals decreased dramatically to 14 %, 24 %, and 42 %, respectively. On the other hand, the fluxes of TC, OTC and CTC were respectively computed to be 2.23 mg/ m2.d, 2.52 mg/ m2.d and 2.87 mg/ m2.d at 10 hr, respectively. At HRT of 1 hr, antibiotic fluxes were on average 4.08 mg TC/ m2.d for TC, 6.72 mg OTC/ m2.d for OTC and 12.12 mg CTC/ m2.d for CTC. When O2-MBfR was operated at 10 hr, the removal rates were found as 53 % of TC, 55 % of OTC and 71 % of CTC. With decreasing HRT three TCs removal decreased dramatically to 21 %, 37 % and 45 % at 5 hr, and 7 %, 24 % and 32 % at 1 hr, respectively. The fluxes of TC, OTC and CTC were respectively 1.57 mg TC/ m2.d, 1.61 mg OTC/ m2.d and 2.08 mg CTC/ m2.d at 10 hr. The fluxes increased with a decrease in HRT due to increasing the loading rates although the performance deteriorated dramatically. At 1 hr HRT fluxes were on average 1.92 mg TC/ m2.d, 7.08 mg OTC/ m2.d and 9.36 mg CTC / m2.d, respectively. Key words: Membrane Biofilm Reactor, Tetracycline, Oxytetracycline, Chlortetracycline, Removal Flux, Equivalent Flux
dc.identifier.citationYILMAZ, M. (2016). Çoklu tetrasiklin grubu karışımının hidrojen ve oksijene dayalı membran biyofilm reaktörlerinde giderimi (Tez No. 432847) [Yüksek lisans tezi, Fırat Üniversitesi].
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=cbOXH84ZayrLjc0tI-QXKukxabelJXwXFjy8H29C1Un2RsUo-A5q_omAE3H3wkdD
dc.identifier.yoktezid432847
dc.language.isotr
dc.publisherFırat Üniveristesi
dc.relation.publicationcategoryTez
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_TEZ_20260511
dc.subjectÇevre Mühendisliği
dc.titleÇOKLU TETRASİKLİN GRUBU KARIŞIMININ HİDROJEN VE OKSİJENE DAYALI MEMBRAN BİYOFİLM REAKTÖRLERİNDE GİDERİMİ
dc.title.alternativeRemoval of multiple tetracyclines mixture in hydrogen and oxygen based membrane biofilm reactors
dc.typeMaster Thesis

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
432847.pdf
Boyut:
1,26 MB
Biçim:
Adobe Portable Document Format