Effects of sex, eye-side, diurnal variation on intraocular pressure in calves

dc.contributor.authorKulualp, K.
dc.contributor.authorKilic, S.
dc.contributor.authorAytekin, O.
dc.date.accessioned2026-08-12T17:18:00Z
dc.date.issued2019
dc.departmentFırat Üniversitesi
dc.description.abstractThe aim of this study was to determine the effects of factors such as sex, eye-side and diurnal variation on intraocular pressure (IOP) values measured by Tono-Pen Vet (R) in healthy calves. Twenty four (12 males, 12 females) calves were used in this study. IOP measurements were performed in the morning (6: 00 a.m.) and at night (8: 00 p.m). Average IOP values in all calves were measured as 17.67 +/- 2.64 mmHg in the morning and 15.52 +/- 2.05 at night and the difference between these two time points was found to be statistically significant (p<0.0001). Average IOP values were measured as 16.04 +/- 2.82 mmHg in males and 17.15 +/- 2.23 mmHg in females with a statistically significant (p<0.05=0.023) difference between them. Average IOP values were 16.81 +/- 2.85 mmHg in right eyes and 16.37 +/- 2.23 mmHg in left eyes and the difference between these values were statistically insignificant (p>0.05). At the end of study, overall average IOP in all calves was measured as 16.59 +/- 2.59 mmHg. The present data showed a significant difference in terms of sex and diurnal variations and a non-significant difference in eye-side. In addition, this study is the first research article in which the intraocular pressure in calves was measured by Tono-Pen Vet
dc.identifier.doi10.24425/pjvs.2018.125609
dc.identifier.endpage74
dc.identifier.issn1505-1773
dc.identifier.issn2300-2557
dc.identifier.issue1
dc.identifier.pmid30997760
dc.identifier.scopus2-s2.0-85064379152
dc.identifier.scopusqualityQ3
dc.identifier.startpage67
dc.identifier.urihttps://doi.org/10.24425/pjvs.2018.125609
dc.identifier.urihttps://hdl.handle.net/11508/52860
dc.identifier.volume22
dc.identifier.wosWOS:000464400200010
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherPolska Akad Nauk, Polish Acad Sciences, Univ Warmia & Mazury Olsztyn
dc.relation.ispartofPolish Journal of Veterinary Sciences
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectcalves
dc.subjectintraocular pressure
dc.subjectTono-Pen Vet (R)
dc.subjectsex
dc.subjecteye-side
dc.subjectdiurnal variation
dc.titleEffects of sex, eye-side, diurnal variation on intraocular pressure in calves
dc.typeArticle

Dosyalar