AN INVESTIGATION ON THE EFFECT OF GLASS FIBER CONTENTS TO THE TOP LOAD IN THE CONCRETE PIPES

dc.contributor.authorYildiz, Servet
dc.contributor.authorUlucan, Zuelfue Cinar
dc.date.accessioned2026-08-12T17:25:20Z
dc.date.issued2008
dc.departmentFırat Üniversitesi
dc.description.abstractIn this study, the variation of top load strength of the concrete pipes containing %0.2, 0.4 and %0.6 fiber-glass (by weight) has been investigated. The concrete pipes have been tested according to the standard procedures (TS 821 EN 1916). From these tests, it is observed that the fracture load of the concrete pipes containing fiberglass is more than that of the concrete pipes without containing fiber-glass. The top loads of the concrete pipes have increased when the fiber-glass rate is increased. In addition, the top pressure load of the concrete pipes obtained under the same conditions was investigated after the pipes in which flew the sewage and rain water were waited under the soil during one year. According to the obtained results, it is seen that after twenty eight days the top load strength concrete pipes containing %0.6 fiber-glass has been increased %21.54 and after one year the top load strength of the concrete pipes containing the same fiber-glass has been increased %27.40. The load-displacement curves have been drawn depending on the test results. It is also seen that the displacement and the fracture load of the concrete pipes have been increased.
dc.identifier.endpage271
dc.identifier.issn1300-1884
dc.identifier.issue2
dc.identifier.orcid0000-0003-0441-8044
dc.identifier.startpage267
dc.identifier.urihttps://hdl.handle.net/11508/54311
dc.identifier.volume23
dc.identifier.wosWOS:000273012500002
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.language.isotr
dc.publisherGazi Univ, Fac Engineering Architecture
dc.relation.ispartofJournal of the Faculty of Engineering and Architecture of Gazi University
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectTop load
dc.subjectfiber glass
dc.subjectconcrete pipe
dc.titleAN INVESTIGATION ON THE EFFECT OF GLASS FIBER CONTENTS TO THE TOP LOAD IN THE CONCRETE PIPES
dc.typeArticle

Dosyalar