Effects of various drilling parameters on bone during implantology: An in vitro experimental study

dc.contributor.authorKaraca, Faruk
dc.contributor.authorAksakal, Bunyamin
dc.date.accessioned2026-08-12T17:04:06Z
dc.date.issued2013
dc.departmentFırat Üniversitesi
dc.description.abstractDue to temperature increase during bone drilling, bone necrosis is likely to occur. To minimize bone tissue damage during drilling, a detailed in vitro experimental study by using fresh calf cortical bones has been performed with various combined drilling parameters, such as: drilling environment, drill diameter, drill speed, drill force, feed-rate and drill coating. Bone temperatures at the drilling sites were recorded with high accuracy using multi-thermocouples mounted around the tibial diaphyseal cortex. It was shown that temperatures increased with increased drill speeds. It also decreased with a higher feed-rate and drill force. It was also observed that TiBN coated drills caused higher temperatures in the bone than the uncoated drills and the temperatures increased with larger drill diameters. Although the influence of Simulated Body Fluid (SBF) on rising temperatures during drilling was higher for the TiBN coated drills, it was observed that these drills caused more damage to the bone structure. In order to minimize or avoid bone defects and necrosis, orthopaedic surgeons should consider the optimum drilling parameters.
dc.identifier.doi10.5277/abb130404
dc.identifier.endpage32
dc.identifier.issn1509-409X
dc.identifier.issue4
dc.identifier.orcid0000-0003-1874-9274
dc.identifier.orcid0009-0007-7644-5785
dc.identifier.orcid0000-0003-4844-9387
dc.identifier.pmid24479623
dc.identifier.scopus2-s2.0-84893011631
dc.identifier.scopusqualityQ4
dc.identifier.startpage25
dc.identifier.urihttps://doi.org/10.5277/abb130404
dc.identifier.urihttps://hdl.handle.net/11508/48581
dc.identifier.volume15
dc.identifier.wosWOS:000332507000004
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherWroclaw Univ Technology, Fac Computer Science & Management
dc.relation.ispartofActa of Bioengineering and Biomechanics
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectorthopaedics
dc.subjectbone drilling
dc.subjecttemperature
dc.subjectbone necrosis
dc.titleEffects of various drilling parameters on bone during implantology: An in vitro experimental study