Sensitive Amperometric Detection of Hydroxylamine at Electropolymerized Curcumin Film Coated Pencil Graphite Electrode

dc.contributor.authorGunes, Mehmet
dc.contributor.authorSap, Ayse
dc.contributor.authorKarakaya, Serkan
dc.contributor.authorYaman, Mehmet
dc.contributor.authorDilgin, Yusuf
dc.date.accessioned2026-08-12T17:20:52Z
dc.date.issued2023
dc.departmentFırat Üniversitesi
dc.description.abstractIn this study, a sensitive electrochemical method was developed for the determination of hydroxylamine (H-A) using a curcumin-modified pencil graphite electrode prepared with the electropolymerization of curcumin (PolyCurc-PGE). The PolyCurc-PGE showed a remarkable electrocatalytic response for H-A oxidation compared with bare PGE. Amperometric and cyclic voltammetric measurements were performed based on the electrocatalytic oxidation of H-A at PolyCurc-PGE. Some parameters, such as monomer concentration, pH, and cycle number during electropolymerization, were optimized to obtain the best electrochemical response of the modified electrode towards H-A. Results show that the PolyCurc-PGE gives a linear response towards H-A oxidation in the range from 0.50 mu M to 500 mu M (R-2=0.9984). In addition, the sensitivity and detection limit (LOD) of PolyCurc-PGE were found to be 5432 mu A mM(-1) cm(2) and 0.15 mu M H-A, respectively. The developed amperometric method was successfully applied to determine H-A in pharmaceutical and water samples, and acceptable results were obtained with high accuracy and precision.
dc.identifier.doi10.1002/slct.202204104
dc.identifier.issn2365-6549
dc.identifier.issue18
dc.identifier.orcid0000-0002-6401-3295
dc.identifier.orcid0000-0002-8390-590X
dc.identifier.scopus2-s2.0-85159137878
dc.identifier.scopusqualityQ3
dc.identifier.urihttps://doi.org/10.1002/slct.202204104
dc.identifier.urihttps://hdl.handle.net/11508/53727
dc.identifier.volume8
dc.identifier.wosWOS:000985043600001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherWiley-V C H Verlag Gmbh
dc.relation.ispartofChemistryselect
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectamperometry
dc.subjectelectrochemistry
dc.subjectelectropolymerization
dc.subjecthydroxylamine
dc.subjectsensors
dc.titleSensitive Amperometric Detection of Hydroxylamine at Electropolymerized Curcumin Film Coated Pencil Graphite Electrode
dc.typeArticle

Dosyalar