Non-linear seismic behavior of historic Adana Great Clock Tower

dc.contributor.authorErkek, Hakan
dc.contributor.authorCalayir, Yusuf
dc.contributor.authorYetkin, Musa
dc.date.accessioned2026-08-12T18:10:42Z
dc.date.issued2024
dc.departmentFırat Üniversitesi
dc.description.abstractIn this study, the non-linear seismic behavior of the historic Adana Great Clock Tower was investigated. The dynamic characteristics (natural frequencies and mode shapes) of the Clock Tower were determined by operational vibration tests. The finite element model of the Clock Tower was manually updated in the light of the experimentally obtained dynamic characteristics. For the updated finite element model, pushover analyses and non-linear time history analyses were performed. Incremental pushover analyses were performed in the x and y directions proportional to the first lateral displacement modes of the Clock Tower in the x and y directions. The time history analyses took into account the Adana-Ceyhan (1998) earthquake acceleration records. Each of the two horizontal components of the earthquake acceleration records was separately scaled according to the design spectrum defined in TBEC-2018 for earthquake levels with a 10 % and 50 % probability of exceedance in 50 years. These scaled earthquake acceleration records were applied to the structure. The two scaled horizontal components for the same earthquake level were rotated 90 degrees and reapplied to the structure. As the response quantities, displacement, base shear force and plastic strains were evaluated.
dc.description.sponsorshipScientific Research Projects Coordination Unit of Fimath;rat University [MF.19.13-ADEP.23.13]
dc.description.sponsorshipThis paper is partially supported by Scientific Research Projects Coordination Unit of F & imath;rat University [MF.19.13-ADEP.23.13] .
dc.identifier.doi10.1016/j.istruc.2024.106704
dc.identifier.issn2352-0124
dc.identifier.orcid0000-0002-6259-4137
dc.identifier.scopus2-s2.0-85196729798
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.istruc.2024.106704
dc.identifier.urihttps://hdl.handle.net/11508/63398
dc.identifier.volume65
dc.identifier.wosWOS:001260340900001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Science Inc
dc.relation.ispartofStructures
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectModel updating
dc.subjectHistorical clock tower
dc.subjectDynamic characteristics
dc.subjectNon-linear seismic behavior
dc.titleNon-linear seismic behavior of historic Adana Great Clock Tower
dc.typeArticle

Dosyalar