Natural convection analysis for both protruding and flush-mounted heaters located in triangular enclosure

dc.contributor.authorKoca, A.
dc.contributor.authorÖztop, Hakan Fehmi
dc.contributor.authorVarol, Y.
dc.date.accessioned2026-08-12T17:14:07Z
dc.date.issued2008
dc.departmentFırat Üniversitesi
dc.description.abstractA numerical was performed analysis on laminar natural convection heat transfer and fluid flow in both protruding heaters (PHs) and flush-mounted heaters (FMHs) located in a triangular enclosure using finite-difference technique. The heaters were isothermal and the tern perature of the inclined wall was lower than that of the heaters while the remaining walls of the triangular enclosure were adiabatic. Results are presented according to the location of the heaters in two cases. In the first case, the PH was located near the vertical wall and the FMH near the right corner. In the second case, the PH was located near the right corner of the enclosure, whereas the FMH was located close to the vertical wall. The governing parameters on natural convection were Rayleigh number (10(4) <= Ra <= 10(6)), dimensionless length of the PH (W-1), dimensionless length of the FMH (W-2), dimensionless height of the PH (Hp), dimensionless distance between the heater and the vertical wall (S-1), dimensionless distance between the PH and the FMH (S-2) and aspect ratio of the triangular enclosure (0.25 <= AR <= 1.0). It was found that better heat transfer occured when the PH was located near the right corner of the triangular enclosure, while the other heater was mounted near the left vertical wall. Heaters behaved as a single heater when they were close to each other.
dc.identifier.doi10.1243/09544062JMES886
dc.identifier.endpage1214
dc.identifier.issn0954-4062
dc.identifier.issue7
dc.identifier.orcid0000-0003-2989-7125
dc.identifier.scopus2-s2.0-69249133712
dc.identifier.scopusqualityQ2
dc.identifier.startpage1203
dc.identifier.urihttps://doi.org/10.1243/09544062JMES886
dc.identifier.urihttps://hdl.handle.net/11508/51696
dc.identifier.volume222
dc.identifier.wosWOS:000258742800009
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherProfessional Engineering Publishing Ltd
dc.relation.ispartofProceedings of the Institution of Mechanical Engineers Part C-Journal of Mechanical Engineering Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectnatural convection
dc.subjectprotruding heater
dc.subjectflush-mounted heater
dc.subjecttriangle
dc.titleNatural convection analysis for both protruding and flush-mounted heaters located in triangular enclosure
dc.typeArticle

Dosyalar