Evaluation of the effect of local Bovine Amniotic Fluid on Osseointegration of Titanium Implants: A Histologic and Histomorphometric Study

dc.contributor.authorIstek, Ozmen
dc.contributor.authorTanrisever, Murat
dc.contributor.authorAydin, Melek Atille
dc.contributor.authorPak, Pinar
dc.contributor.authorEroksuz, Hatice
dc.contributor.authorKarabulut, Burak
dc.contributor.authorDundar, Serkan
dc.date.accessioned2026-08-12T17:07:48Z
dc.date.issued2024
dc.departmentFırat Üniversitesi
dc.description.abstractThe aim of this study was to histologically and histomorphometrically investigate the effect of locally applied bovine amniotic fluid (BAF) on osseointegration levels in implants. Adult female Sprague-Dawley rats weighing 300-350 g were used as subjects. The rats were divided into two groups: the sham-operated control group (n=10) and the local BAF group (n=10). Implant cavities were created in the tibias of all subjects under sterile saline cooling with rotating instruments. Local BAF was applied to all implant sockets before the implants were placed. Rats were sacrificed after a four-week osseointegration period. Histological staining was performed using hematoxylin and eosin staining to analyze the osseointegration. Examinations of the bone implant connection (BIC) and peri-implant bone formation (PBF) were performed using a light microscope and an image analyzer. As a result of the analysis, the mean BIC value was 40.3 +/- 4.9 for the sham-operated control group and 45.2 +/- 7.7 for the local BAF group. The mean PBF was 39.9 +/- 6.3 for the sham control group and 40.5 +/- 5.7 for the local BAF group. A statistically significant difference was found between the sham control group and the local BAF group for the BIC and PBF values (P>0.05; P >0.05; P : 0.11; P : 0.83). The application of local BAF to the implant socket did not have a clear positive effect on implant osseointegration. More studies are needed to clarify the association between local BAF and osseointegration.
dc.description.sponsorshipThe authors wish to thank Implance Dental Implant Systems, AGS Medical, Istanbul, Turkiye for the manufacturing of the implants which used in this study.
dc.identifier.doi10.52973/rcfcv-e34417
dc.identifier.issn0798-2259
dc.identifier.issue2
dc.identifier.orcid0000-0001-6849-0868
dc.identifier.orcid0000-0003-3815-8543
dc.identifier.orcid0000-0002-8002-0006
dc.identifier.orcid0000-0002-4907-6159
dc.identifier.scopus2-s2.0-85204195855
dc.identifier.scopusqualityQ4
dc.identifier.urihttps://doi.org/10.52973/rcfcv-e34417
dc.identifier.urihttps://hdl.handle.net/11508/49795
dc.identifier.volume34
dc.identifier.wosWOS:001309145900017
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherUniv Zulia, Facultad Ciencias Veterinarias
dc.relation.ispartofRevista Cientifica-Facultad de Ciencias Veterinarias
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectBovine amniotic fluid
dc.subjecttitanium implant
dc.subjectosseointegration
dc.subjectbone implant connection
dc.subjectbone implant contact
dc.titleEvaluation of the effect of local Bovine Amniotic Fluid on Osseointegration of Titanium Implants: A Histologic and Histomorphometric Study
dc.title.alternativeEvaluación del efecto del líquido amniótico bovino local sobre la osteointegración de implantes de titanio: un estudio histológico e histomorfométrico
dc.typeArticle

Dosyalar