Comparison of two methods for malondialdehyde measurement

dc.contributor.authorAl-Fawaeir, Saad
dc.contributor.authorÖzgür Akgül, E.
dc.contributor.authorÇayci, Tuncer
dc.contributor.authorDemirin, Hilmi
dc.contributor.authorKurt, Yasemin Gülcan
dc.contributor.authorAydin, Ibrahim
dc.contributor.authorErbil, M. Kemal
dc.date.accessioned2026-08-12T16:07:37Z
dc.date.issued2011
dc.departmentFırat Üniversitesi
dc.description.abstractAim In this study, we aimed to measure malondialdehyde levels by two different methods and compare these methods. Material and Methods Serum malondialdehyde levels of 60 volunteers were measured with thiobarbituric acid test and high pressure liquid chromatography after derivatization of malondialdehyde with 2,4 dinitrophenylhydrazine and these two methods were compared. Results A statistically significant difference (p<0.001) has been found in serum malondialdehyde levels measured by high pressure liquid chromatography (1.85±0.09 ?mol/L) and spectrophotometry (2.47±0.18 ?mol/L). Cohesion between measurements made by two different methods have been evaluated and the interclass correlation coefficient has been found as 0.365 (p=0.042). Statistically significant, weak-mild degree correlation has been found between measurements (r=0.284, p=0.028). Conclusions High pressure liquid chromatography method for malondialdehyde measurement after derivatization with 2,4 dinitrophenylhydrazine provided a more accurate and sensitive assessment of lipid peroxidation than the conventional spectrophotometric thiobarbituric acid method.
dc.identifier.doi10.4328/JCAM.209
dc.identifier.endpage14
dc.identifier.issn1309-0720
dc.identifier.issue2
dc.identifier.scopus2-s2.0-79952263975
dc.identifier.scopusqualityN/A
dc.identifier.startpage11
dc.identifier.trdizinid128190
dc.identifier.urihttps://doi.org/10.4328/JCAM.209
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/128190
dc.identifier.urihttps://hdl.handle.net/11508/40827
dc.identifier.volume2
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.language.isotr
dc.publisherDerman Medical Publishing
dc.relation.ispartofJournal of Clinical and Analytical Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_Scopus_20260511
dc.subjectHigh Pressure Liquid Chromatography; Lipid Peroxidation; Malondialdehide; Oxidative Stress; Spectrophotometric Method
dc.titleComparison of two methods for malondialdehyde measurement
dc.title.alternativeMalondialdehid Ölçümünde iki Yöntemin Karşılaştırılması
dc.typeArticle

Dosyalar