Factors Affecting the Combined Spinal Epidural Block Spreading Level

dc.contributor.authorÖnal, Selami Ateş
dc.contributor.authorYaşar, Mehmet Akif
dc.contributor.authorAkin, Mustafa
dc.contributor.authorBayar, Mustafa Kemal
dc.contributor.authorErhan, Ömer Lütfi
dc.contributor.authorÖzmiş, Metin
dc.date.accessioned2026-08-12T16:13:19Z
dc.date.issued2003
dc.departmentFırat Üniversitesi
dc.description.abstractCombined spinal epidural block (CSEB) can enhance the spreading level of local anaesthetic (LA). Eighty patients (21-78 yr, ASA physical status I and II) were randomly allocated to four groups of 20 patients each. CSEB was achieved at the L3-L4 interspace with the patient in the sitting position. Study 1: to assess the compressive effect of the epidural LA on the dural bag: Group I/Study (1-S): CSEB with 0.5% plain bupivacaine 4 mL in the subarachnoid space, 0.9% saline 20 mL in the epidural space; Group II/Control (1-C): Spinal block with 0.5% plain bupivacaine 4 mL in the subarachnoid space; Study 2: to assess the passage of the LA through the dural hole: Group III/ Study (2-S): CSEB with 0.9% saline 4 mL in the subarachnoid space, 0.5% bupivacaine 20 mL in the epidural space; Group IV/Control (2-C): Epidural block with 0.5% bupivacaine 20 mL in the epidural space. Assessment of the spreading levels of block was performed at 5 min intervals during 20 minutes. Comparisons of the spreading levels were significantly differents between the Groups 1-S and 1-C at 5 min and 10 min; significantly differents between the Groups 2-S and 2-C at 15 min and 20 min (p<0.05). Linear regression analysis revealed significant correlation between body mass index and the cephalic spreading level of CSEB. We confirmed that increasing the spinal sensitive block level with CSEB may be done by the compression of the volume given to epidural space which causes enhanced total spreading and also by the entrance of the bupivacaine from dural hole which was given to epidural space.
dc.identifier.endpage352
dc.identifier.issn1304-0871
dc.identifier.issue7
dc.identifier.scopus2-s2.0-0142105817
dc.identifier.scopusqualityN/A
dc.identifier.startpage347
dc.identifier.urihttps://hdl.handle.net/11508/42964
dc.identifier.volume31
dc.indekslendigikaynakScopus
dc.language.isotr
dc.relation.ispartofTurk Anesteziyoloji ve Reanimasyon Dernegi Dergisi
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_Scopus_20260511
dc.subjectBupivacaine; Combined spinal epidural block; Spreading level
dc.titleFactors Affecting the Combined Spinal Epidural Block Spreading Level
dc.title.alternativeKombine Spinal Epidural Anestezide Yayilim Seviyesini Etkileyen Faktörler
dc.typeArticle

Dosyalar