Influence of glazing area on optimum thickness of insulation for different wall orientations

dc.contributor.authorOzel, Meral
dc.date.accessioned2026-08-12T17:49:39Z
dc.date.issued2019
dc.departmentFırat Üniversitesi
dc.description.abstractIn this paper, influence of glazing area on optimum insulation thickness is numerically investigated considering wall orientations in the climatic conditions of Elazig, Turkey. For this aim, annual heating and cooling transmission loads are calculated according to the glazing area percentage (GAP) on the wall having various insulation thicknesses. Calculations are repeated for different wall orientations and two types of glazing (single glass and double glass) by varying GAP from 0 to 100%. Then, the transmission loads are used to determine the optimum thickness of insulation. It is obvious that as GAP increases, the optimum insulation thicknesses and energy savings decrease for all wall orientations and two types of glazing while payback periods increases. The results show that optimum insulation thicknesses of a south-facing wall are obtained to be 8.5, 6.5, 5.5 and 4 cm for values 0%, 20%, 40% and 60% of GAP in case of single glazing, respectively while they are obtained to be 8.5, 4, 3.5 and 2.5 cm in case of double glazing. Consequently, it is revealed that the glazing area in the wall, type of glazing and wall orientations have a significant effect on transmission loads and optimum insulation thickness.
dc.identifier.doi10.1016/j.applthermaleng.2018.10.089
dc.identifier.endpage780
dc.identifier.issn1359-4311
dc.identifier.issn1873-5606
dc.identifier.scopus2-s2.0-85055971310
dc.identifier.scopusqualityQ1
dc.identifier.startpage770
dc.identifier.urihttps://doi.org/10.1016/j.applthermaleng.2018.10.089
dc.identifier.urihttps://hdl.handle.net/11508/61900
dc.identifier.volume147
dc.identifier.wosWOS:000454974700070
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofApplied Thermal Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectAnnual heating arid cooling loads
dc.subjectGlazing area percentage
dc.subjectType of glazing
dc.subjectWall orientations
dc.subjectOptimum insulation thickness
dc.titleInfluence of glazing area on optimum thickness of insulation for different wall orientations
dc.typeArticle

Dosyalar