Comparison of LabUMat-with-UriSed and iQ®200 fully automatic urine sediment analysers with manual urine analysis

dc.contributor.authorAkin, Okhan Kadir
dc.contributor.authorSerdar, Muhittin A.
dc.contributor.authorCizmeci, Zeynep
dc.contributor.authorGenc, Ozlem
dc.contributor.authorAydin, Suleyman
dc.date.accessioned2026-08-12T17:14:05Z
dc.date.issued2009
dc.departmentFırat Üniversitesi
dc.description.abstractUrine analysis is one of the most common tests for assessing urinary-tract and kidney diseases. In recent years there have been new developments in the automation of this test. The objective of the present study was to compare the performances of two urine sediment analysers, namely LabUMat with UriSed (77 Elektronika Kft, Budapest, Hungary) and iQ (R) 200 (Iris Diagnostics, Chatsworth, CA, U.S.A.), with the KOVA (R) method for manual urine measurement by evaluating the results in terms of similar parameters (cells or particles per lower-power field or high-power field). The results obtained using the UriSed and iQ (R) 200 analysers were more reproducible (7.1-30.2 and 14.9-35.4% respectively) than those obtained using the manual technique (17.9-44.4%). Significant correlations were established among the three techniques in the evaluation of leucocytes, erythrocytes and epithelial cells. Although the UriSed, iQ (R) 200 and visual-microscopic measurements were in agreement, confirmation of the results from automated methods by manual urine analyses is significantly useful, especially for pathological cases that were close to the limits of the techniques.
dc.identifier.doi10.1042/BA20080188
dc.identifier.endpage144
dc.identifier.issn0885-4513
dc.identifier.pmid19021504
dc.identifier.scopus2-s2.0-67649668858
dc.identifier.scopusqualityQ1
dc.identifier.startpage139
dc.identifier.urihttps://doi.org/10.1042/BA20080188
dc.identifier.urihttps://hdl.handle.net/11508/51677
dc.identifier.volume53
dc.identifier.wosWOS:000266788400008
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherPortland Press Ltd
dc.relation.ispartofBiotechnology and Applied Biochemistry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectfully automatic urine sediment analysis
dc.subjectiQ (R) 200 urine analyser
dc.subjectKOVA (R) system
dc.subjectLabUMat with UriSed urine analyser
dc.subjectvisual manual urine sediment analysis
dc.titleComparison of LabUMat-with-UriSed and iQ®200 fully automatic urine sediment analysers with manual urine analysis
dc.typeArticle

Dosyalar