In-situ thermal response test for ground source heat pump system in Elazig, Turkey

dc.contributor.authorEsen, Hikmet
dc.contributor.authorInalli, Mustafa
dc.date.accessioned2026-08-12T17:45:36Z
dc.date.issued2009
dc.departmentFırat Üniversitesi
dc.description.abstractGround source heat pump (GSHP) systems exchange heat with the ground, often through a vertical, U-tube, borehole heat exchanger (BHE). The performance of this U-tube BHE depends on the thermal properties of the ground formation, as well as grout or backfill in the borehole, The design and economic probability of GSHP systems need the thermal conductivity of geological structure and thermal resistance of BHE. Thermal response test (TRT) method allows the in-situ determination of the thermal conductivity (lambda) of the ground formation in the vicinity of a BHE, as well as the effective thermal resistance (R-b) of this latter. Thermal properties measured in laboratory experiments do not comply with data of in-situ conditions. The main goal has been to determine same in-situ ground type of BHE, including the effect of borehole's depths (60 m: VB2; 90 m: VB3). As shown in these results, X and Rb Of the VB2/VB3 boreholes are determined as 1.70/1.70 W m(-1) K-1 and 0.05/0.03 KW-1 m, respectively. (C) 2008 Elsevier B.V. All rights reserved.
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [106Y188 (2006-2007)]
dc.description.sponsorshipThe authors would like to acknowledge the Scientific and Technological Research Council of Turkey (TUBITAK) for its financial support through contract no. 106Y188 (2006-2007) and Dr. Bekir Turgut for his contribution to this project.
dc.identifier.doi10.1016/j.enbuild.2008.11.004
dc.identifier.endpage401
dc.identifier.issn0378-7788
dc.identifier.issn1872-6178
dc.identifier.issue4
dc.identifier.orcid0000-0002-6260-4948
dc.identifier.orcid0000-0001-8802-8080
dc.identifier.scopus2-s2.0-61349190942
dc.identifier.scopusqualityQ1
dc.identifier.startpage395
dc.identifier.urihttps://doi.org/10.1016/j.enbuild.2008.11.004
dc.identifier.urihttps://hdl.handle.net/11508/60750
dc.identifier.volume41
dc.identifier.wosWOS:000264704700004
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Science Sa
dc.relation.ispartofEnergy and Buildings
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectGround source heat pump
dc.subjectVertical heat exchanger
dc.subjectThermal response test
dc.subjectThermal conductivity
dc.subjectThermal resistance
dc.titleIn-situ thermal response test for ground source heat pump system in Elazig, Turkey
dc.typeArticle

Dosyalar