Diagnosis of breast cancer in light microscopic and mammographic images textures using relative entropy via kernel estimation

dc.contributor.authorKorkmaz, Sevcan Aytac
dc.contributor.authorKorkmaz, Mehmet Fatih
dc.contributor.authorPoyraz, Mustafa
dc.date.accessioned2026-08-12T17:32:36Z
dc.date.issued2016
dc.departmentFırat Üniversitesi
dc.description.abstractThe aim of this article was to provide early detection of breast cancer by using both mammography and histopathology images of the same patient. When the studies in the literature are examined, it is seen that the mammography and histopathology images of the same patient are not used together for early diagnosis of breast cancer. Mammographic and microscopic images can be limited when using only one of them for the early detection of the breast cancer. Therefore, multi-modality solutions that give more accuracy results than single solutions have been realized in this paper. 3 x 50 microscopic (histopathology) and 3 x 50 mammography image sets have been taken from Firat University Medicine Faculty Pathology and Radiology Laboratories, respectively. Optimum feature space has been obtained by minimum redundancy and maximum relevance via mutual information method applying to the 3 x 50 microscopic and mammography images. Then, probabilistic values of suspicious lesions in the image for selected features have been found by exponential curve fitting. Jensen Shannon, Hellinger, and Triangle measurements have been used for the diagnosis of breast cancer. It has been proved that these measures have been related to each other. Weight values for selected each feature have been found using these measures. These weight values have been used in object function. Afterward, histopathology and mammography images have been classified as normal, malign, and benign utilizing object function. In the result of this classifier, the accuracy of diagnosis of breast cancer has been estimated probabilistically. Furthermore, classifications have been probabilistically visualized on a pie chart. Consequently, the performances of Jensen Shannon, Hellinger, and Triangle measures have been compared with ROC analysis using histopathology and mammography test images. It has been observed that Jensen Shannon measure has higher performance than Hellinger and Triangle measures. Accuracy rates of histopathology and mammography images in Jensen Shannon measure have been found to 99 and 98 %, respectively.
dc.identifier.doi10.1007/s11517-015-1361-0
dc.identifier.endpage573
dc.identifier.issn0140-0118
dc.identifier.issn1741-0444
dc.identifier.issue4
dc.identifier.pmid26345243
dc.identifier.scopus2-s2.0-84940948532
dc.identifier.scopusqualityQ2
dc.identifier.startpage561
dc.identifier.urihttps://doi.org/10.1007/s11517-015-1361-0
dc.identifier.urihttps://hdl.handle.net/11508/56706
dc.identifier.volume54
dc.identifier.wosWOS:000373021100001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer Heidelberg
dc.relation.ispartofMedical & Biological Engineering & Computing
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectBreast histopathology images
dc.subjectMammography
dc.subjectJensen Shannon divergence
dc.subjectHellinger measure
dc.subjectTriangle distance
dc.subjectFeature selection
dc.subjectMutual information
dc.titleDiagnosis of breast cancer in light microscopic and mammographic images textures using relative entropy via kernel estimation
dc.typeArticle

Dosyalar