Evaluation of 4 Point-of-Care Units for the Determination of Blood L-Lactate Concentration in Cattle
| dc.contributor.author | Karapinar, T. | |
| dc.contributor.author | Kaynar, O. | |
| dc.contributor.author | Hayirli, A. | |
| dc.contributor.author | Kom, M. | |
| dc.date.accessioned | 2026-08-12T17:48:04Z | |
| dc.date.issued | 2013 | |
| dc.department | Fırat Üniversitesi | |
| dc.description.abstract | BackgroundDespite being used commonly in bovine medicine, information on reliability of point-of-care (POC) lactate meters is limited. ObjectiveTo determine the validity of 4 commercially available POC lactate meters in cattle. AnimalsCattle with various diseases (n=120). MethodsBlood samples collected from the jugular vein were processed immediately on POC lactate meters. Plasma l-lactate concentration was measured by the enzymatic-colorimetric method (ELISA). Data were subjected to Friedman's test for comparison, Passing-Bablok regression and Bland-Altman plot analyses for reliability, and receiver operating characteristics analysis for sensitivity (Se) and specificity (Sp). ResultsThe POC lactate meters were highly correlated with ELISA (r=0.98-0.99) despite disagreements among units. When regressed on ELISA, blood l-lactate concentrations generated from Accutrend Plus and Lactate Pro were linear up to 16.6 and 15.7mmol/L, respectively, whereas those generated from i-STAT and Lactate Scout were linear up to 19.5 and 19.7mmol/L, respectively. All POC lactate meters had a Se of 100% with Sp of 95.7-98.6% at a plasma l-lactate cut-off concentration of 4mmol/L. i-STAT had the best accuracy (99.0%) and precision (99.8%), the best linear fit (y=-0.13+1.04X) yielding the lowest bias (-6.6%) as well as the highest Se (100%) and Sp (98.6%). Conclusions and Clinical ImportanceDespite high correlation with the reference method, dilution is needed for Accutrend Plus/Lactate Pro and i-STAT/Lactate Scout if concentrations >15 and 20mmol/L, respectively. i-STAT provided the most accurate and precise results. | |
| dc.description.sponsorship | Scientific and Technological Research Council of Turkey (TUBITAK) project [111O045] | |
| dc.description.sponsorship | This research was supported by The Scientific and Technological Research Council of Turkey (TUBITAK) project no: 111O045. We thank Asst. Prof. Bulent Cavusoglu (Department of Electrical and Electronics Engineering, Ataturk University) for MATLAB usage. | |
| dc.identifier.doi | 10.1111/jvim.12204 | |
| dc.identifier.endpage | 1603 | |
| dc.identifier.issn | 0891-6640 | |
| dc.identifier.issn | 1939-1676 | |
| dc.identifier.issue | 6 | |
| dc.identifier.pmid | 24118259 | |
| dc.identifier.scopus | 2-s2.0-84887615675 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 1596 | |
| dc.identifier.uri | https://doi.org/10.1111/jvim.12204 | |
| dc.identifier.uri | https://hdl.handle.net/11508/61284 | |
| dc.identifier.volume | 27 | |
| dc.identifier.wos | WOS:000326972600040 | |
| dc.identifier.wosquality | Q1 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Wiley-Blackwell | |
| dc.relation.ispartof | Journal of Veterinary Internal Medicine | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WoS_20260511 | |
| dc.subject | Accuracy | |
| dc.subject | Bovine | |
| dc.subject | Portable lactate meter | |
| dc.subject | Precision | |
| dc.subject | Sensitivity | |
| dc.subject | Specificity | |
| dc.title | Evaluation of 4 Point-of-Care Units for the Determination of Blood L-Lactate Concentration in Cattle | |
| dc.type | Article |







