Reliability and Validity of the L Test in Persons With Multiple Sclerosis

dc.contributor.authorBilek, Furkan
dc.contributor.authorDemir, Caner F.
dc.date.accessioned2026-08-12T17:21:38Z
dc.date.issued2025
dc.departmentFırat Üniversitesi
dc.description.abstractThe L Test has been developed to assess balance and gait disorders. Our aim in this study was to estimate the test-retest reliability and validity of the L Test when used with 82 persons with multiple sclerosis (PwMS). For these participants, we examined the degree of agreement between the results of a first and second administration of the L Test (separated by one day), using Bland-Altman analysis and intra-class correlation coefficients (ICCs). We computed minimal detectable change (MDC) and standard error of measurement (SEM) values for the L Test and evaluated concurrent validity by correlating L Test results with the Timed Up and Go test (TUG) and the 10-minute Walk Test (10MWT). Prior to administering these measurements, we randomized the sequence of the test administrations to our participants. The Bland-Altman analysis showed that L Test was reproducible, with upper and lower limits of agreement of 0.99 and -1.45 seconds, respectively. The L Test demonstrated excellent test-retest reliability, with an ICC value of 0.996 (95% CI: 0.994-0.998). Cronbach's alpha coefficient was 0.996. The performance of the L Test is measured by seconds required to complete the task, and we found the L Test SEM value to be 0.35 seconds, and its MDC value to be 0.97 seconds. The L Test showed a strong correlation with both the TUG test (rho = 0.936; p < .001) and the 10MWT (rho = 0.925; p < .001). We concluded that the L Test is a reliable and valid \ tool for assessing functional mobility and balance in PwMS.
dc.identifier.doi10.1177/00315125241298728
dc.identifier.endpage277
dc.identifier.issn0031-5125
dc.identifier.issn1558-688X
dc.identifier.issue2
dc.identifier.orcid0000-0003-1567-7201
dc.identifier.pmid39506918
dc.identifier.scopus2-s2.0-85209218116
dc.identifier.scopusqualityQ3
dc.identifier.startpage262
dc.identifier.urihttps://doi.org/10.1177/00315125241298728
dc.identifier.urihttps://hdl.handle.net/11508/54011
dc.identifier.volume132
dc.identifier.wosWOS:001350688700001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSage Publications Inc
dc.relation.ispartofPerceptual and Motor Skills
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectmultiple sclerosis
dc.subjectL Test
dc.subjectgait
dc.subjectbalance
dc.subjectreliability
dc.subjectvalidity
dc.titleReliability and Validity of the L Test in Persons With Multiple Sclerosis
dc.typeArticle