Effect of ultrasonic scaling and air polishing on the surface roughness of polyetheretherketone (PEEK) materials

dc.contributor.authorDemirci, Fatih
dc.contributor.authorErdem, Merve Birgealp
dc.contributor.authorTekin, Samet
dc.contributor.authorCaliskan, Cevdet
dc.date.accessioned2026-08-12T17:20:29Z
dc.date.issued2022
dc.departmentFırat Üniversitesi
dc.description.abstractPurpose: To evaluate the effects of ultrasonic scaling (US) and air polishing (AP) on four polyetheretherketone (PEEK) composites. Methods: One hundred-twenty 15 x 3 mm discs of PEEK specimens were divided into four groups (n=30): Unfilled PEEK(U-PEEK), carbon fiber-reinforced PEEK(CFR-PEEK), glass fiber-reinforced PEEK(GFR-PEEK), and ceramic-filled PEEK(CF-PEEK). Each group was further divided into three subgroups (n = 10): control, US, and AP. Profilometry and scanning electron microscopy were used to analyze and evaluate surface roughness (SR). Statistical analyses of the data obtained were conducted using Shapiro-Wilk, Welch, and Games-Howell tests. Results: When the SR values of the specimens with US cleaning were evaluated, a statistically significant difference was found between the groups (P< 0.05). When the SR values of the specimens with AP cleaning were analyzed, there was a statistically significant difference in the CF-PEEK group (P< 0.05), whereas the other groups were not significantly different (P> 0.05). More studies are needed on CFR-PEEK and GFR-PEEK materials offered as alternatives to CF-PEEK in dentistry.
dc.description.sponsorshipAdiyaman University Research Project Council (ADYUBAPB) [DHFDUP/2019-0004]
dc.description.sponsorshipThis study was supported by a grant of the Adiyaman University Research Project Council (ADYUBAPB) -DHFDUP/2019-0004).
dc.identifier.endpage204
dc.identifier.issn0894-8275
dc.identifier.issue4
dc.identifier.orcid0000-0002-8744-5592
dc.identifier.orcid0000-0001-8883-8307
dc.identifier.pmid35986936
dc.identifier.scopus2-s2.0-85137008680
dc.identifier.scopusqualityQ3
dc.identifier.startpage200
dc.identifier.urihttps://hdl.handle.net/11508/53566
dc.identifier.volume35
dc.identifier.wosWOS:000893228400007
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherMosher & Linder, Inc
dc.relation.ispartofAmerican Journal of Dentistry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectIn-Vitro Evaluation
dc.subjectRestorative Materials
dc.subjectBacterial Adhesion
dc.subjectBiofilm Formation
dc.subjectTopography
dc.subjectRoot
dc.titleEffect of ultrasonic scaling and air polishing on the surface roughness of polyetheretherketone (PEEK) materials
dc.typeArticle

Dosyalar