Thermal analysis and energy requirement of wall and window components for buildings with different orientations

dc.contributor.authorOzel, Meral
dc.contributor.authorSengur, Serhat
dc.date.accessioned2026-08-12T17:02:00Z
dc.date.issued2025
dc.departmentFırat Üniversitesi
dc.description.abstractThis research highlights the importance of wall insulation, type of glazing and glazing area to reduce energy consumption and to ensure thermal comfort in residential buildings. With the appropriate combination of design parameters such as window glass area, glazing type, wall orientation and wall insulation, heating and cooling loads and therefore energy requirements can be substantially reduced. The main goal of this research is to analyze the thermal performance and energy requirements of the wall and window components that can make residential buildings energy efficient, considering building orientations for four cities of T & uuml;rkiye. Firstly, heat gain and losses through walls and windows are numerically researched. The heat transmission loads through wall are computed employing an implicit finite difference procedure. Secondly, the ratio of window to wall area is also investigated from the transmission loads point of view. Then, heating and cooling energy requirements and costs are also separately determined for walls consisting of single and double-glazed windows. Consequently, it is observed that the orientation, climate conditions, geographical location, type of glazing and insulation have a notable effect on heat transmission and energy requirement. The results also show that the highest heating energy requirement and cost are acquired for the north orientation in Kars, where the heating load is dominant while the highest cooling energy requirement and cost are acquired for the west (or east) orientation in Antalya, where the cooling load is dominant. It is revealed that the double glazing significantly reduces these energy requirements. The results show that this reduction in heating need for Kars is 61.91%, 45.81%, 49.01% and 49.01% for South, North, East and West orientations, respectively. On the other hand, it is seen that this decrease in cooling need for Antalya is 30.45%, 33.30%, 25.17% and 25.17%. Also, the double glazing appears to be more effective at reducing heating demand than at reducing cooling demand. The results acquired in this work will be very beneficial in the selection of glass type and the glazing area, taking into account the wall direction, when designing exterior walls of residential buildings in different climatic zones.
dc.identifier.doi10.14744/thermal.0000931
dc.identifier.endpage549
dc.identifier.issn2148-7847
dc.identifier.issue2
dc.identifier.scopus2-s2.0-105011603314
dc.identifier.scopusqualityQ2
dc.identifier.startpage519
dc.identifier.trdizinid1361575
dc.identifier.urihttps://doi.org/10.14744/thermal.0000931
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1361575
dc.identifier.urihttps://hdl.handle.net/11508/47984
dc.identifier.volume11
dc.identifier.wosWOS:001455373600017
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherYildiz Technical Univ
dc.relation.ispartofJournal of Thermal Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectClimate Zones
dc.subjectEnergy Requirements
dc.subjectHeat Gain and Losses
dc.subjectNoninsulated Wall and Insulated Wall
dc.subjectSingle-Glazing and Double-Glazing
dc.titleThermal analysis and energy requirement of wall and window components for buildings with different orientations