Investigation of heat transfer and pressure drop in a concentric heat exchanger with snail entrance

dc.contributor.authorDurmus, A
dc.contributor.authorDurmus, A
dc.contributor.authorEsen, M
dc.date.accessioned2026-08-12T17:41:27Z
dc.date.issued2002
dc.departmentFırat Üniversitesi
dc.description.abstractIn this study, in order to increase heat transfer in concentric double-pipe heat exchangers by passive method, snail which is mounted at inlet of the inner pipe and assumed as a swirl generator was used. In the experimental set-up, cold air in ambient conditions was passed through the inner pipe while hot water was flowing through the annulus. The effects of a snail on the heat transfer and pressure drop were investigated for parallel and counter-flow, and obtained Nusselt numbers (Nu) were compared with those found, using a standard correlation such as Dittus-Boelter equation given for axial flows in smooth pipes. The results were correlated in the form of Nusselt number as a function of Reynolds number, Prandtl number and the swirling angle. An augmentation of up to 120% in Nusselt number was obtained in the swirl flow for counter-flow and 45 swirling angle. Though the swirl flow effect of the snail caused some increase in pressure drop, this effect was unimportant compared with the improvement in heat transfer capacity. (C) 2002 Elsevier Science Ltd. All rights reserved.
dc.identifier.doi10.1016/S1359-4311(01)00078-3
dc.identifier.endpage332
dc.identifier.issn1359-4311
dc.identifier.issue3
dc.identifier.orcid0000-0001-6543-8095
dc.identifier.scopus2-s2.0-0036489143
dc.identifier.scopusqualityQ1
dc.identifier.startpage321
dc.identifier.urihttps://doi.org/10.1016/S1359-4311(01)00078-3
dc.identifier.urihttps://hdl.handle.net/11508/59345
dc.identifier.volume22
dc.identifier.wosWOS:000173636000006
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofApplied Thermal Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectexperimental
dc.subjectconcentric heat exchanger
dc.subjectsnail
dc.subjectswirl flow
dc.subjectswirling angle
dc.subjectheat transfer enhancement
dc.subjectpumping power
dc.titleInvestigation of heat transfer and pressure drop in a concentric heat exchanger with snail entrance
dc.typeArticle

Dosyalar