Investigation of the most suitable location of insulation applying on building roof from maximum load levelling point of view

dc.contributor.authorOzel, M.
dc.contributor.authorPihtili, K.
dc.date.accessioned2026-08-12T17:44:47Z
dc.date.issued2007
dc.departmentFırat Üniversitesi
dc.description.abstractIn this study, the maximum load levelling of periodic heat flux entering a room through a composite roof consisting of different insulation layer has been evaluated for different insulation positions in the roof. A numerical model based on implicit finite difference scheme was applied for 12 different roof configurations during typical winter and summer days. For this purpose, total insulation thickness was kept constant and insulation was placed as equally two pieces and as equally three pieces in different locations within the roof thickness. Then, insulation layers were moved I cm at a time across the roof thickness for 12 different configurations. Maximum and minimum values of periodic heat fluxes for each sweeping process in the roof were calculated for achieving the maximum levelling of the heat flux entering through the roof. It was found that the best load levelling was achieved in the case where three pieces insulation of equal thickness were placed one at the outdoor surface of the roof, the second piece of insulation was placed in the middle of the roof and third piece of insulation was placed at the indoor surface of the roof. (c) 2006 Elsevier Ltd. All rights reserved.
dc.identifier.doi10.1016/j.buildenv.2006.05.006
dc.identifier.endpage2368
dc.identifier.issn0360-1323
dc.identifier.issn1873-684X
dc.identifier.issue6
dc.identifier.scopus2-s2.0-33847032440
dc.identifier.scopusqualityQ1
dc.identifier.startpage2360
dc.identifier.urihttps://doi.org/10.1016/j.buildenv.2006.05.006
dc.identifier.urihttps://hdl.handle.net/11508/60418
dc.identifier.volume42
dc.identifier.wosWOS:000245060500018
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofBuilding and Environment
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectbuilding roof
dc.subjectinsulation layers
dc.subjectmaximum load levelling
dc.titleInvestigation of the most suitable location of insulation applying on building roof from maximum load levelling point of view
dc.typeArticle

Dosyalar