Evaluation of the seismic response of reinforced concrete buildings in the light of lessons learned from the February 6, 2023, Kahramanmaraş, Türkiye earthquake sequences

dc.contributor.authorYon, Burak
dc.contributor.authorDedeoglu, Ibrahim Ozgur
dc.contributor.authorYetkin, Musa
dc.contributor.authorErkek, Hakan
dc.contributor.authorCalayir, Yusuf
dc.date.accessioned2026-08-12T18:10:49Z
dc.date.issued2025
dc.departmentFırat Üniversitesi
dc.description.abstractOn 6 February 2023, two significant seismic events occurred in the southeastern region of T & uuml;rkiye. The seismic activity, which was perceptible in numerous countries beyond T & uuml;rkiye, resulted in a considerable number of fatalities. A considerable number of individuals lost their lives and were rendered homeless as a result of the disaster. Two of the most significant factors contributing to the occurrence of these tragedies are the magnitude of the earthquake and structural deficiencies. The present study is concerned with a detailed analysis of these two factors. This study initially considers the seismicity of the region where the earthquakes that occurred on 6 February 2023 took place, as well as the seismic characteristics of these earthquakes. Subsequently, the findings of the field studies conducted in Hatay, Ad & imath;yaman, Kahramanmara & scedil; and Malatya, the cities where the earthquakes caused the most destruction, are presented. The objective of the field study is to ascertain the collapse patterns, structural damages and the factors influencing these damages in reinforced concrete structures in the region. The primary causes of damage to structures can be attributed to several factors, including the presence of a strong beam-weak column mechanism, the soft story-weak story mechanism, the pounding effect, the short column damage, the long cantilever and overhangs, the short beam damage, the buckling damage, the torsion effect, the quality of the materials, the insufficient transverse reinforcement, the compressive failure due to over-reinforcement, the corrosion effect, the damage to reinforced concrete shear walls, the infill wall damage, and the damage caused by the soil and foundation system. These causes have been evaluated and recommendations have been formulated to prevent structural damage.
dc.description.sponsorshipScientific and Technological Research Council of Turkiye (TUBIdot;TAK)
dc.description.sponsorshipOpen access funding provided by the Scientific and Technological Research Council of Turkiye (TUB & Idot;TAK). The authors received no support for their work. They did all the work with their means.
dc.identifier.doi10.1007/s11069-024-06859-9
dc.identifier.endpage909
dc.identifier.issn0921-030X
dc.identifier.issn1573-0840
dc.identifier.issue1
dc.identifier.orcid0000-0001-6008-9586
dc.identifier.orcid0000-0001-5356-6655
dc.identifier.orcid0000-0002-6259-4137
dc.identifier.orcid0000-0001-5155-6963
dc.identifier.scopus2-s2.0-85200594325
dc.identifier.scopusqualityQ1
dc.identifier.startpage873
dc.identifier.urihttps://doi.org/10.1007/s11069-024-06859-9
dc.identifier.urihttps://hdl.handle.net/11508/63443
dc.identifier.volume121
dc.identifier.wosWOS:001286533400002
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofNatural Hazards
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subject6 February 2023 earthquakes
dc.subjectSeismic characteristics
dc.subjectSeismicity of the region
dc.subjectReinforced concrete buildings
dc.subjectField study
dc.subjectStructural damage
dc.titleEvaluation of the seismic response of reinforced concrete buildings in the light of lessons learned from the February 6, 2023, Kahramanmaraş, Türkiye earthquake sequences
dc.typeArticle

Dosyalar