EFFECTS OF VARIABLE TEMPERATURE ON MIXED CONVECTION OF A CU-WATER NANOFLUID IN A DOUBLE-LID-DRIVEN POROUS ENCLOSURE WITH ACTIVE MIDDLE VERTICALWALL

dc.contributor.authorBegum, A. Shamadhani
dc.contributor.authorNithyadevi, N.
dc.contributor.authorÖztop, Hakan Fehmi
dc.contributor.authorAbu-Hamdeh, Nidal
dc.date.accessioned2026-08-12T17:34:45Z
dc.date.issued2019
dc.departmentFırat Üniversitesi
dc.description.abstractThis work is focused on the numerical modeling of laminar mixed convection in a double-lid-driven porous enclosure with sinusoidal heating on vertical walls, thermally insulated horizontal walls, and walls saturated with a Cu-water nanofluid. The dispersed nanoparticle-filled porous enclosure has a moving hot wall at the center. The generalized governing equations with the non-Darcy porous media model are solved numerically using the finite volume method. The present results are found to be in good agreement with the numerical results available in the open literature. The results of the fluid flow and heat transfer characteristics are reported for the Richardson number (Ri) from 0.01 to 100, Darcy number (Da) from 10(-3) to 10(-6), heat generation parameter (S) from 0 to 10, porosity (epsilon) of the porous medium from 0.2 to 0.9, solid volume fraction of nanoparticle (phi) from 0.0 to 0.2, and height-to-length aspect ratio (AR) from 1/3 to 3 for the fixed Prandtl number (Pr = 6.2). It is found that the presence of copper nanoparticles in the fluid-saturated porous media assures the enhancement in average Nusselt number value, and the existence of a moving vertical wall helps to maximize the overall heat transfer performance.
dc.identifier.doi10.1615/JPorMedia.2019028911
dc.identifier.endpage497
dc.identifier.issn1091-028X
dc.identifier.issn1934-0508
dc.identifier.issue4
dc.identifier.orcid0000-0002-6080-0355
dc.identifier.orcid0000-0002-4151-6260
dc.identifier.scopus2-s2.0-85064246034
dc.identifier.scopusqualityQ2
dc.identifier.startpage481
dc.identifier.urihttps://doi.org/10.1615/JPorMedia.2019028911
dc.identifier.urihttps://hdl.handle.net/11508/57264
dc.identifier.volume22
dc.identifier.wosWOS:000465186100007
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherBegell House Inc
dc.relation.ispartofJournal of Porous Media
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectmixed convection
dc.subjectenclosure
dc.subjectporous medium
dc.subjectsinusoidal heating
dc.subjectnanofluid
dc.titleEFFECTS OF VARIABLE TEMPERATURE ON MIXED CONVECTION OF A CU-WATER NANOFLUID IN A DOUBLE-LID-DRIVEN POROUS ENCLOSURE WITH ACTIVE MIDDLE VERTICALWALL
dc.typeArticle

Dosyalar