Design parameters for a solar heating system with an underground cylindrical tank

dc.contributor.authorInalli, M
dc.date.accessioned2026-08-12T17:41:18Z
dc.date.issued1998
dc.departmentFırat Üniversitesi
dc.description.abstractWe have performed a theoretical analysis of a solar heating system with an underground cylindrical tank. A two-dimensional ground-temperature distribution is used around the tank. Heat-transfer problems are solved by application of complex, finite-Fourier-transform technique and a finite difference method. A 25- and a 100-house community are considered for the performance calculation. The effects of collector area, tank volume, number of houses, and depth of the tank have been investigated far istanbul (40 degrees N). Isotherms of the ground around the tank are illustrated in graphical form. (C) 1998 Elsevier Science Ltd. All rights reserved.
dc.identifier.doi10.1016/S0360-5442(98)00058-9
dc.identifier.endpage1027
dc.identifier.issn0360-5442
dc.identifier.issue12
dc.identifier.orcid0000-0002-6260-4948
dc.identifier.scopus2-s2.0-0032468040
dc.identifier.scopusqualityQ1
dc.identifier.startpage1015
dc.identifier.urihttps://doi.org/10.1016/S0360-5442(98)00058-9
dc.identifier.urihttps://hdl.handle.net/11508/59258
dc.identifier.volume23
dc.identifier.wosWOS:000077018500001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofEnergy
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectStorage
dc.subjectModel
dc.titleDesign parameters for a solar heating system with an underground cylindrical tank
dc.typeArticle

Dosyalar