Spotlights on some electrocardiographic paradigms: How should we evaluate normal reference values of Tp-Te interval, Tp-Te dispersion and Tp-Te/QT ratio?

dc.contributor.authorYilmaz, Mucahid
dc.contributor.authorKayancicek, Hidayet
dc.contributor.authorGozel, Nevzat
dc.contributor.authorBilen, Mehmet Nail
dc.contributor.authorKurtoglu, Ertugrul
dc.contributor.authorSecen, Ozlem
dc.contributor.authorKeles, Fikret
dc.date.accessioned2026-08-12T17:18:39Z
dc.date.issued2020
dc.departmentFırat Üniversitesi
dc.description.abstractBackground: Experimental and clinical studies evaluating the Tp-Te interval and Tp-Te/QT ratio have reported conflicting data. The overlap between normal Tp-Te/QT ratios (0.17 +/- 0.02-0.27 +/- 0.06 ms) and pathological values (0.20 +/- 0.03-0.30 +/- 0.06 ms) measured in earlier studies has raised questions about this ECG measurement technique. Objectives: To analyze normal values of the Tp-Te interval, Tp-Te dispersion Tp-Te(d) and the Tp-Te/QT ratio based on electrocardiographic (ECG) assessment across sex and age groups in a healthy Turkish population. Material and methods: A total of 1,485 healthy participants (723 men) were enrolled into the study. The age of the participants ranged 17-75 years and they did not have either any cardiovascular/systemic disorders or risk factors for atherosclerosis which were detected with physical examination and laboratory tests. The Tp-Te interval, Tp-Te(d) and Tp-Te/QT ratio were determined from V1-V6 derivations. Results: For the entire study, the median Tp-Te interval was 66.0 (64.0-70.0) ms, the Tp-Te(d) was 15.0 (10.0-20.0) ms, and the Tp-Te/QT ratio was 0.18 (0.17-0.19). The Pearson's correlation test demonstrated that the Tp-Te/QT ratio significantly correlated with older age (r = 0.297; p < 0.0001), left ventricular (LV) end-diastolic diameter (LVEDD; r = 0.481; p < 0.0001), body mass index (BMI; r = 0.421; p < 0.0001), body surface area (BSA; r = 0.191; p < 0.0001), LV end-diastolic volume (LVEDV; r = 0.484; p < 0.0001), LVEDV index (r = 0.450; p < 0.0001), LV mass (r = 0.548; p < 0.0001), and LV mass index (r = 0.539; p < 0.0001). Conclusions: The reference values for Tp-Te interval, Tp-Te(d) and Tp-Te/QT ratio are associated with age, BMI, BSA, LVEDV, LVEDV index, LV mass, and LV mass index. These structural elements should be considered when using these ECG parameters for assessing repolarization inhomogeneity. These findings may guide further studies assessing healthy and diseased populations.
dc.identifier.doi10.17219/acem/117684
dc.identifier.endpage1099
dc.identifier.issn1899-5276
dc.identifier.issn2451-2680
dc.identifier.issue9
dc.identifier.orcid0000-0001-9592-5986
dc.identifier.orcid0000-0003-4657-8003
dc.identifier.orcid0000-0002-4585-3707
dc.identifier.orcid0000-0003-1468-2930
dc.identifier.orcid0000-0002-6769-8875
dc.identifier.pmid32937041
dc.identifier.scopus2-s2.0-85092318081
dc.identifier.scopusqualityQ1
dc.identifier.startpage1091
dc.identifier.urihttps://doi.org/10.17219/acem/117684
dc.identifier.urihttps://hdl.handle.net/11508/53123
dc.identifier.volume29
dc.identifier.wosWOS:000577257100009
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherWroclaw Medical Univ
dc.relation.ispartofAdvances in Clinical and Experimental Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectTp-Te interval
dc.subjectTp-Te/QT ratio
dc.subjectTp-Te dispersion
dc.subjectLV mass
dc.subjectLV mass index
dc.titleSpotlights on some electrocardiographic paradigms: How should we evaluate normal reference values of Tp-Te interval, Tp-Te dispersion and Tp-Te/QT ratio?
dc.typeArticle