Energy and exergy assessments of a perlite expansion furnace in a plaster plant

dc.contributor.authorGurturk, Mert
dc.contributor.authorÖztop, Hakan Fehmi
dc.contributor.authorHepbasli, Arif
dc.date.accessioned2026-08-12T17:48:03Z
dc.date.issued2013
dc.departmentFırat Üniversitesi
dc.description.abstractIn this study, energy and exergy assessments of a perlite expansion furnace in a plaster factory are performed. Chemical properties of the perlite and its application areas are described. Energy and exergy relations according to the First and Second Law of Thermodynamics are derived. Energy and exergy efficiencies, losses and exergy destructions are calculated based on the measurements obtained from the system. Evaluations of environmental impact, energy management and economic are finally generalized according to the obtained results. Energy and exergy efficiencies of the furnace are determined to be 66% and 26%, respectively. Reference temperature effects on exergy efficiency, destruction and sustainability index are also presented. The results showed that the furnace has not been well designed in terms of thermal aspects due to high energy and exergy losses and the manufacturer producing the perlite expanded should establish an energy management structure. (C) 2013 Elsevier Ltd. All rights reserved.
dc.description.sponsorshipFirat University [TEKF.13.01]
dc.description.sponsorshipThe authors would like to thank Firat University Project Support Unit with the project number TEKF.13.01 and Aralci Company in Elazig, Turkey for their valuable contribution to this work. They are also very grateful to the reviewers due their appropriate and constructive suggestions as well as their proposed corrections, which have been utilized in improving the quality of the paper.
dc.identifier.doi10.1016/j.enconman.2013.06.049
dc.identifier.endpage497
dc.identifier.issn0196-8904
dc.identifier.issn1879-2227
dc.identifier.orcid0000-0003-0380-5704
dc.identifier.scopus2-s2.0-84881111595
dc.identifier.scopusqualityQ1
dc.identifier.startpage488
dc.identifier.urihttps://doi.org/10.1016/j.enconman.2013.06.049
dc.identifier.urihttps://hdl.handle.net/11508/61264
dc.identifier.volume75
dc.identifier.wosWOS:000326661400053
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofEnergy Conversion and Management
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectExergy
dc.subjectEnergy audit
dc.subjectPerlite
dc.subjectPerlite expansion furnace
dc.subjectFurnace
dc.titleEnergy and exergy assessments of a perlite expansion furnace in a plaster plant
dc.typeArticle

Dosyalar