Water length and height effects on the earthquake behavior of arch dam-reservoir-foundation systems

dc.contributor.authorSevim, Baris
dc.contributor.authorAltunsik, Ahmet Can
dc.contributor.authorBayraktar, Alemdar
dc.contributor.authorAkkose, Mehmet
dc.contributor.authorCalayir, Yusuf
dc.date.accessioned2026-08-12T17:14:28Z
dc.date.issued2011
dc.departmentFırat Üniversitesi
dc.description.abstractIn this study, water length and height effects on the earthquake behavior of arch dam-reservoir-foundation systems are purposed. The study can be classified into two parts. In the first part, in order to obtain a realistic 3D arch dam-reservoir-foundation model, water length effects on the behavior of the arch dam systems are investigated. For this purpose a double curvature arch dam is modeled by forming four different water lengths related to dam Height (H) as H, 2H, 3H and 4H. Each model is analyzed in time domain and the realistic model is obtained according to the analyses results. In the second part, water height effects on the behavior of the arch dam system are investigated. The arch dam obtained from first part of the study is modeled by forming four different water heights related to dam Height (H) as 0H, 0.33H, 0.66H and H. The behavior of the dam, reservoir and foundation are expressed in terms of displacements using Lagrangian approach. The foundation is taken into account as massless; behavior of reservoir is assumed to be linearly elastic, inviscid and irrotational. In this study, all systems are modeled by ANSYS finite element program and analyses are performed using IMPVALL/I-ELC180 component of Imperial Valley (1940) earthquake. Dynamic equations of motions are solved by using Newmark integration algorithm. It is seen that both water length and height affect the earthquake behavior of the arch dams considerably.
dc.identifier.doi10.1007/s12205-011-0815-7
dc.identifier.endpage303
dc.identifier.issn1226-7988
dc.identifier.issn1976-3808
dc.identifier.issue2
dc.identifier.orcid0000-0003-3828-3571
dc.identifier.orcid0000-0002-8973-9228
dc.identifier.scopus2-s2.0-79251611978
dc.identifier.scopusqualityQ2
dc.identifier.startpage295
dc.identifier.urihttps://doi.org/10.1007/s12205-011-0815-7
dc.identifier.urihttps://hdl.handle.net/11508/51842
dc.identifier.volume15
dc.identifier.wosWOS:000286667200011
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherKorean Society of Civil Engineers-Ksce
dc.relation.ispartofKsce Journal of Civil Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectarch dam-reservoir-foundation system
dc.subjectearthquake behavior
dc.subjectlagrangian approach
dc.subjectwater length and height effect
dc.titleWater length and height effects on the earthquake behavior of arch dam-reservoir-foundation systems
dc.typeArticle

Dosyalar