The effect of different variables on push-out tests in 3D-printed oval and round- shaped root canals: a methodological study
| dc.contributor.author | Gok, Tuba | |
| dc.contributor.author | Cankaya, Guzide | |
| dc.contributor.author | Sen, Bilge Hakan | |
| dc.date.accessioned | 2026-08-12T17:39:35Z | |
| dc.date.issued | 2025 | |
| dc.department | Fırat Üniversitesi | |
| dc.description.abstract | Objective: This study aimed to evaluate the effect of slice thickness (ST), plunger size (PS), shape and region of the root canal on push-out tests using standardized artificial root canals. Materials and methods: Two teeth with round and oval root canal anatomy were selected using cone beam computed tomography.Teeth were prepared, scanned with micro computed tomography and stereolithography data were obtained. Seventy-two round and 72 long oval artificial root canals were produced using a 3D printer. Root canals were obturated, then divided into two main groups (oval-round) and further divided into six subgroups (n = 12) according to ST (1, 1.5, and 2-mm) and PS (0.5, 0.75, and 1-mm). Push-out tests were performed and dislocation resistance values were calculated. The data were analyzed using the ANOVA two-way test (p = 0.05). Results: Different STs showed similar results in oval canals (p > 0.05). 1-mm ST showed higher results in round canals (p < 0.05). There was a significant difference between 0.75 and 1-mm PSs (p < 0.05). Middle and coronal regions showed similar results in oval canals (p > 0.05), and coronal region showed lower results in round canals (p < 0.05). Conclusion: ST, PS, root canal shape and region variables affected the dislocation resistance of core material in standardized root-filled canals. | |
| dc.description.sponsorship | Scientific and Technological Research Council of Turkiye (3001 Starting R&D Projects Funding Program) [118S811] | |
| dc.description.sponsorship | This study was supported by the Scientific and Technological Research Council of Turkiye (3001 Starting R&D Projects Funding Program, Grant number: 118S811-Institute Share Allowance) . The funding sources had no involvement in the study design, collection, analysis and interpretation of data, preparation of the manuscript, or in the decision to publish. | |
| dc.identifier.doi | 10.2340/aos.v84.42958 | |
| dc.identifier.endpage | 92 | |
| dc.identifier.issn | 0001-6357 | |
| dc.identifier.issn | 1502-3850 | |
| dc.identifier.orcid | 0000-0003-1173-909X | |
| dc.identifier.pmid | 39945029 | |
| dc.identifier.scopus | 2-s2.0-85218774195 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 86 | |
| dc.identifier.uri | https://doi.org/10.2340/aos.v84.42958 | |
| dc.identifier.uri | https://hdl.handle.net/11508/58887 | |
| dc.identifier.volume | 84 | |
| dc.identifier.wos | WOS:001445553400001 | |
| dc.identifier.wosquality | Q2 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Medical Journal Sweden Ab | |
| dc.relation.ispartof | Acta Odontologica Scandinavica | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_WoS_20260511 | |
| dc.subject | 3D printing | |
| dc.subject | artificial root canal | |
| dc.subject | dislocation resistance | |
| dc.subject | push-out test | |
| dc.subject | root canal treatment | |
| dc.title | The effect of different variables on push-out tests in 3D-printed oval and round- shaped root canals: a methodological study | |
| dc.type | Article |







