The effect of different variables on push-out tests in 3D-printed oval and round- shaped root canals: a methodological study

dc.contributor.authorGok, Tuba
dc.contributor.authorCankaya, Guzide
dc.contributor.authorSen, Bilge Hakan
dc.date.accessioned2026-08-12T17:39:35Z
dc.date.issued2025
dc.departmentFırat Üniversitesi
dc.description.abstractObjective: This study aimed to evaluate the effect of slice thickness (ST), plunger size (PS), shape and region of the root canal on push-out tests using standardized artificial root canals. Materials and methods: Two teeth with round and oval root canal anatomy were selected using cone beam computed tomography.Teeth were prepared, scanned with micro computed tomography and stereolithography data were obtained. Seventy-two round and 72 long oval artificial root canals were produced using a 3D printer. Root canals were obturated, then divided into two main groups (oval-round) and further divided into six subgroups (n = 12) according to ST (1, 1.5, and 2-mm) and PS (0.5, 0.75, and 1-mm). Push-out tests were performed and dislocation resistance values were calculated. The data were analyzed using the ANOVA two-way test (p = 0.05). Results: Different STs showed similar results in oval canals (p > 0.05). 1-mm ST showed higher results in round canals (p < 0.05). There was a significant difference between 0.75 and 1-mm PSs (p < 0.05). Middle and coronal regions showed similar results in oval canals (p > 0.05), and coronal region showed lower results in round canals (p < 0.05). Conclusion: ST, PS, root canal shape and region variables affected the dislocation resistance of core material in standardized root-filled canals.
dc.description.sponsorshipScientific and Technological Research Council of Turkiye (3001 Starting R&D Projects Funding Program) [118S811]
dc.description.sponsorshipThis study was supported by the Scientific and Technological Research Council of Turkiye (3001 Starting R&D Projects Funding Program, Grant number: 118S811-Institute Share Allowance) . The funding sources had no involvement in the study design, collection, analysis and interpretation of data, preparation of the manuscript, or in the decision to publish.
dc.identifier.doi10.2340/aos.v84.42958
dc.identifier.endpage92
dc.identifier.issn0001-6357
dc.identifier.issn1502-3850
dc.identifier.orcid0000-0003-1173-909X
dc.identifier.pmid39945029
dc.identifier.scopus2-s2.0-85218774195
dc.identifier.scopusqualityQ2
dc.identifier.startpage86
dc.identifier.urihttps://doi.org/10.2340/aos.v84.42958
dc.identifier.urihttps://hdl.handle.net/11508/58887
dc.identifier.volume84
dc.identifier.wosWOS:001445553400001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherMedical Journal Sweden Ab
dc.relation.ispartofActa Odontologica Scandinavica
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subject3D printing
dc.subjectartificial root canal
dc.subjectdislocation resistance
dc.subjectpush-out test
dc.subjectroot canal treatment
dc.titleThe effect of different variables on push-out tests in 3D-printed oval and round- shaped root canals: a methodological study
dc.typeArticle