Effect of micro-arc oxidation coatings with graphene oxide and graphite on osseointegration of titanium implants-an in vivo study

dc.contributor.authorTekin, Bahar
dc.contributor.authorDundar, Serkan
dc.contributor.authorTekin, Samet
dc.contributor.authorSukuroglu, Ebru Emine
dc.contributor.authorKhurshid, Zohaib
dc.contributor.authorEzgi, Yusuf
dc.contributor.authorFaheemuddin, Muhammad
dc.date.accessioned2026-08-12T17:38:39Z
dc.date.issued2024
dc.departmentFırat Üniversitesi
dc.description.abstractBackground: This in vivo study evaluated the effect of graphene oxide and graphite coatings, coupled with the micro-arc oxidation (MAO) surface roughening technique, known for their mechanical strength, chemical stability, and antibacterial properties. The main objective was to assess the degree of improvement in osseointegration of titanium implants resulting from these interventions. Materials and methods: In this study, 32 female rats were utilized and randomly allocated into four groups (n = 8 each): machined surface titanium implants (control), those roughened by the MAO method, those coated with graphene oxide-doped MAO, and those with a graphite-doped MAO coating. Titanium implants were surgically placed in the right tibia of the rats. Rats undergoing no additional procedures during the 4-week experimental period were sacrificed at the end. Then, the implants and surrounding bone tissues were separated and embedded in acrylic blocks for reverse torque analysis. Using a digital torque device, the rotational force was applied to all samples using a hex driver and racquet until implant separation from the bone occurred, with the corresponding values recorded on the digital display. Then, statistical analysis was performed to analyze the data. Results: No statistically significant difference between the groups was observed in the biomechanical bone-implant connection levels (N/cm) (P = 0.268). Post-hoc tests were not required because no discernible differences were identified between the groups. Conclusion: Within the scope of this study, implants treated with the MAO method, along with those coated with graphene oxide- and graphite-doped MAO method, did not exhibit significant superiority in terms of osseointegration compared to machined surface titanium implants.
dc.identifier.doi10.1016/j.sdentj.2024.01.013
dc.identifier.endpage595
dc.identifier.issn1013-9052
dc.identifier.issn1658-3558
dc.identifier.issue4
dc.identifier.orcid0000-0001-8638-5471
dc.identifier.orcid0000-0002-8744-5592
dc.identifier.orcid0000-0003-2797-2806
dc.identifier.orcid0000-0001-8883-8307
dc.identifier.orcid0000-0001-7998-7335
dc.identifier.pmid38690378
dc.identifier.scopus2-s2.0-85184760369
dc.identifier.scopusqualityQ2
dc.identifier.startpage591
dc.identifier.urihttps://doi.org/10.1016/j.sdentj.2024.01.013
dc.identifier.urihttps://hdl.handle.net/11508/58532
dc.identifier.volume36
dc.identifier.wosWOS:001230812100001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofSaudi Dental Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectCoating
dc.subjectDental implants
dc.subjectGraphite
dc.subjectGraphene oxide
dc.subjectMicro -arc oxidation
dc.subjectOsseointegration
dc.titleEffect of micro-arc oxidation coatings with graphene oxide and graphite on osseointegration of titanium implants-an in vivo study
dc.typeArticle

Dosyalar