Energy-Performance Evaluation with Revit Analysis of Mathematical-Model-Based Optimal Insulation Thickness

dc.contributor.authorBalo, Figen
dc.contributor.authorUlutas, Alptekin
dc.date.accessioned2026-08-12T17:38:00Z
dc.date.issued2023
dc.departmentFırat Üniversitesi
dc.description.abstractThis study investigates the optimum insulation thickness value using MATLAB Optimization Toolbox based on a mathematical model for sandwich walls that are formed with different insulation-building materials by different fuel types for a particular city located in the second climatic region of Turkey. In the second stage of study, using the BIM-based Revit simulation program, a building was designed with the same building-insulation materials under the same climate conditions. The six different wall performances were compared for the designed building. The study proposes a comprehensive approach by combining technical and economic factors in the sustainable design of buildings. The computational results indicate that using different energy alternatives has a significant impact on the air quality in residential areas. The lowest value is reached when natural gas is used. The energy cost savings change from 7.56 to 14.12 TRY/m(2) for external walls. While payback periods vary between 2.15 and 3.76 years for external walls, the lowest period for all wall types is obtained for electricity, which has a high cost. The optimum insulation thickness for 10 years of lifetime varies between 0.02 and 0.16 m. This study reflects that the highest optimal insulating thickness is reached when electricity is utilized as the energy source for all wall types. According to the Revit analysis, the lowest energy consumption of 21,677 kWh during one year using natural gas was obtained for a building material of porous light brick and an insulation material of glass wool.
dc.identifier.doi10.3390/buildings13020408
dc.identifier.issn2075-5309
dc.identifier.issue2
dc.identifier.orcid0000-0001-5886-730X
dc.identifier.orcid0000-0002-8130-1301
dc.identifier.scopus2-s2.0-85149214293
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.3390/buildings13020408
dc.identifier.urihttps://hdl.handle.net/11508/58266
dc.identifier.volume13
dc.identifier.wosWOS:000938337600001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherMdpi
dc.relation.ispartofBuildings
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectoptimum insulation thickness
dc.subjectenergy efficiency
dc.subjectenvironmental impact
dc.titleEnergy-Performance Evaluation with Revit Analysis of Mathematical-Model-Based Optimal Insulation Thickness
dc.typeArticle