Ability and utility of diffusion-weighted MRI with different b values in the evaluation of benign and malignant renal lesions

dc.contributor.authorDoganay, S.
dc.contributor.authorKocakoc, E.
dc.contributor.authorCicekci, M.
dc.contributor.authorAglamis, S.
dc.contributor.authorAkpolat, N.
dc.contributor.authorOrhan, I.
dc.date.accessioned2026-08-12T17:14:34Z
dc.date.issued2011
dc.departmentFırat Üniversitesi
dc.description.abstractAIM: To evaluate the ability and the utility of diffusion-weighted (DW) magnetic resonance imaging (MRI) with high and low b values to visualize benign and malignant renal lesions, and to determine which b value (b = 100, 600, or 1000 s/mm(2)) was most useful in differentiating benign from malignant renal lesions. MATERIALS AND METHODS: Fifty-eight patients with 67 renal lesions and 50 normal contralateral kidneys (as control) were enrolled in the study. DW imaging was performed with b values of 100, 600, and 1000 s/mm(2). Results of the histopathological evaluation were compared with the DW MRI results. Apparent diffusion coefficient (ADC) values, and the sensitivity and specificity for differentiating malignant renal lesions from benign renal lesions were calculated for each b value. RESULTS: The mean ADC values of normal renal parenchyma with b = 100, 600, and 1000 s/mm(2) values were (3.14 +/- 0.54) x 10(-3), (2.52 +/- 0.30) x 10(-3), and (2.16 +/- 0.43) x 10(-3) mm(2)/s, respectively. The mean ADC values of benign renal lesions (n = 35) with b = 100, 600, and 1000 s/mm(2) values were (2.88 +/- 0.88) x 10(-3), (2.58 +/- 0.91) x 10(-3), and (2.10 +/- 0.93) x 10(-3) mm(2)/s, respectively. The mean ADC values of malignant renal lesions (n = 32) with b = 100, 600, and 1000 values were (2.74 +/- 0.58) x 10(-3), (2.09 +/- 0.63) x 10(-3), and (1.66 +/- 0.51) x 10(-3) mm(2)/s, respectively. Using DW imaging malignant renal lesions could be differentiated from benign renal lesions, and also angiomyolipomas and oncocytomas could be differentiated from renal cell carcinoma. CONCLUSIONS: DW MRI with quantitative ADC measurements can be useful in the differentiation of benign and malignant renal lesions. High b values (b = 600 and 1000 s/mm(2)) had the best specificity and sensitivity. (C) 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
dc.identifier.doi10.1016/j.crad.2010.11.013
dc.identifier.endpage425
dc.identifier.issn0009-9260
dc.identifier.issn1365-229X
dc.identifier.issue5
dc.identifier.orcid0000-0002-9138-2117
dc.identifier.pmid21334604
dc.identifier.scopus2-s2.0-79953029147
dc.identifier.scopusqualityQ2
dc.identifier.startpage420
dc.identifier.urihttps://doi.org/10.1016/j.crad.2010.11.013
dc.identifier.urihttps://hdl.handle.net/11508/51862
dc.identifier.volume66
dc.identifier.wosWOS:000289606100005
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherW B Saunders Co Ltd
dc.relation.ispartofClinical Radiology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectLiver
dc.subjectAbdomen
dc.subjectMasses
dc.titleAbility and utility of diffusion-weighted MRI with different b values in the evaluation of benign and malignant renal lesions
dc.typeArticle

Dosyalar