The environmental impact of optimum insulation thickness for external walls and flat roofs of building in Turkey's different degree-day regions

dc.contributor.authorUcar, Aynur
dc.date.accessioned2026-08-12T16:35:26Z
dc.date.issued2009
dc.departmentFırat Üniversitesi
dc.description.abstractThe optimum insulation-thickness for the flat roofs and walls of buildings energy savings over a lifetime of 10 years and payback periods are calculated for three different insulation materials and the twelve various cities from four climate zones of Turkey. Stropor, polystyrene and rockwool as insulation material are selected. In this study, it is calculated the value of the amount of the net energy savings using the P-1-P-2 method. The results show that optimum insulation thicknesses vary between 1.46 and 14.1 cm,, energy savings vary between 3.67 and 11.78 $/m(2), and payback periods vary between 2.07 and 3.25 years depending on the city and the wall type. The lowest value of optimum insulation thickness is obtained as 1.77 cm for roof 3 in Antalya, while the highest value is found as 8.16 cm in Bayburt. In this study, environmental impact of optimum insulation thickness in external walls and roofs has been investigated. It is found that when the optimum insulation thickness is used, the amount of fuel consumption and the emissions of CO2 and SO2 are decreased by 88%.
dc.identifier.endpage69
dc.identifier.issn1308-772X
dc.identifier.issue1
dc.identifier.scopus2-s2.0-77957311695
dc.identifier.scopusqualityN/A
dc.identifier.startpage49
dc.identifier.urihttps://hdl.handle.net/11508/44896
dc.identifier.volume24
dc.identifier.wosWOS:000272362200005
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherSila Science
dc.relation.ispartofEnergy Education Science and Technology Part A-Energy Science and Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectInsulation thickness
dc.subjectEnergy savings
dc.subjectEnvironmental impact
dc.titleThe environmental impact of optimum insulation thickness for external walls and flat roofs of building in Turkey's different degree-day regions