The comparison of temporal temperature measurement method by non-contact infrared thermometer with other body temperature measurement methods

dc.contributor.authorHakan, Nilay
dc.contributor.authorOkumus, Nurullah
dc.contributor.authorAydin, Mustafa
dc.contributor.authorKucukozkan, Tuncay
dc.contributor.authorTuygun, Nilden
dc.contributor.authorZenciroglu, Aysegul
dc.date.accessioned2026-08-12T17:00:43Z
dc.date.issued2017
dc.departmentFırat Üniversitesi
dc.description.abstractObjective: To evaluate the effectiveness of non-contact infrared thermometer (NCIT) by comparing with other thermometers and/or body temperature measurement methods. Methods: The patients were divided into 3 groups: 0-1 year-old babies, >16 year-old female patients, and 1-16 year-old children. The body temperature of all patients was measured by NCIT at the temporal region, and the digital thermometer through the axillary region. Moreover, body temperature of the children was measured with tympanic thermometer and of adults with digital thermometer through oral route. Results: When compared to other temperature measurement methods, in all patients, the temporal temperature was not statistically different to that of rectal temperature (p>0.05); but it was 0.6 degrees C higher than axillary (p<0.001), 0.3 degrees C higher than oral (p<0.001), and 0.1 degrees C higher than tympanic temperatures (p<0.001). If the rectal temperature of >= 38 degrees C has been taken as a reference value for fever; the sensitivity, specificity, positive and negative predictive values for average temporal temperature were 48.5, 99.5, 88.9, and 96.3%, respectively. Based on visual inspection of the Bland-Altman plots, NCIT underestimated the higher body temperatures which resulted in a low sensitivity. Conclusion: Our findings indicate that NCITs can be used as a rapid, hygienic and noninvasive method for excluding fever in children. However, this method has low sensitivity for detecting fever compared to that of rectal measurement and other noninvasive techniques. Although temporal temperature seems to be close to rectal temperature, this method is not ideal for detecting febrile patients yet.
dc.identifier.doi10.5222/buchd.2017.141
dc.identifier.endpage146
dc.identifier.issn2146-2372
dc.identifier.issn1309-9566
dc.identifier.issue2
dc.identifier.orcid0000-0003-4280-3883
dc.identifier.startpage141
dc.identifier.urihttps://doi.org/10.5222/buchd.2017.141
dc.identifier.urihttps://hdl.handle.net/11508/47333
dc.identifier.volume7
dc.identifier.wosWOS:000418200900010
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherDr Behcet Uz Cocuk Hastaliklari ve Cerrahisi
dc.relation.ispartofIzmir Dr Behcet Uz Cocuk Hastanesi Dergisi
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectFever
dc.subjectbody temperature measurement
dc.subjectnon-contact infrared thermometer
dc.subjectchildren
dc.titleThe comparison of temporal temperature measurement method by non-contact infrared thermometer with other body temperature measurement methods
dc.typeArticle