The comparison of cyclopentolate and atropine in patients with refractive accommodative esotropia by means of retinoscopy, autorefractometry and biometric lens thickness
| dc.contributor.author | Çelebi, S | |
| dc.contributor.author | Aykan, Ü | |
| dc.date.accessioned | 2026-08-12T16:34:03Z | |
| dc.date.issued | 1999 | |
| dc.department | Fırat Üniversitesi | |
| dc.description.abstract | Purpose: In this study, we aimed to compare the cycloplegic effect of cyclopentolate HCI 1% and atropine sulphate 1% in patients with refractive accommodative esotropia by means of retinoscopy, autorefractometer and the measurement of lens thickness by biometry. Methods: Thirty-two patients with refractive accommodative esotropia aged from 5 to 10 (mean 6.8+/-1.4), had a deviation under 10 prism diopters, and underwent retinoscopic, autorefractometric and biometric study in dry and wet conditions. Results: The retinoscopic, autorefractometric and biometric findings of the right eye were 5.10+/-1.21 diopter (D), 5.03+/-1.20 D, 3.43+/-0.16 mm with cyclopentolate, and 5.2+/-1.2 D, 5.2+/-1.2 D, 3.4+/-0.1 mm with atropine. In the left eye, the measurements were 5.2+/-1.4 D, 5.1+/-1.4 D, 3.5+/-0.2 mm with cyclopentolate, and 5.3+/-1.2 D, 5.20+/-1.3 D, 3.4+/-0.2 mm with atropine, respectively. When these obtained data were compared by the Student's t test no statistical significance was found (p>0.05). Conclusions: We suggest that the cyclopentolate cycloplegia applied to the patients with refractive accommodative esotropia is sufficient to produce good cycloplegia, with an effect similar to atropine. | |
| dc.identifier.doi | 10.1034/j.1600-0420.1999.770414.x | |
| dc.identifier.endpage | 429 | |
| dc.identifier.issn | 1395-3907 | |
| dc.identifier.issue | 4 | |
| dc.identifier.pmid | 10463415 | |
| dc.identifier.scopus | 2-s2.0-0032773844 | |
| dc.identifier.scopusquality | N/A | |
| dc.identifier.startpage | 426 | |
| dc.identifier.uri | https://doi.org/10.1034/j.1600-0420.1999.770414.x | |
| dc.identifier.uri | https://hdl.handle.net/11508/44288 | |
| dc.identifier.volume | 77 | |
| dc.identifier.wos | WOS:000081698100014 | |
| dc.identifier.wosquality | N/A | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Scriptor Publisher | |
| dc.relation.ispartof | Acta Ophthalmologica Scandinavica | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_WoS_20260511 | |
| dc.subject | refractive accommodative esotropia | |
| dc.subject | cycloplegia | |
| dc.subject | cyclopentolate | |
| dc.subject | atropine | |
| dc.subject | retinoscopy | |
| dc.subject | autorefractometer | |
| dc.subject | biometry | |
| dc.subject | lens thickness | |
| dc.title | The comparison of cyclopentolate and atropine in patients with refractive accommodative esotropia by means of retinoscopy, autorefractometry and biometric lens thickness | |
| dc.type | Article |







