Static and dynamic analyses of fracture fixation bone-plate systems for different plate materials and dimensions

dc.contributor.authorErdem, Serkan
dc.contributor.authorGur, Mustafa
dc.contributor.authorKaman, Mete Onur
dc.date.accessioned2026-08-12T17:05:09Z
dc.date.issued2018
dc.departmentFırat Üniversitesi
dc.description.abstractBACKGROUND: Various techniques have been developed in the treatment of fractures. One of these techniques is the internal fixation, which has an important place in practice. OBJECTIVE: In this study, fractured tibia bone has been treated with implants as numerically to investigate the stress behavior and the effect of plate material, shape and dimensions under pressure load. METHODS: The outer part of the bone is chosen as orthotropic and the inner part is chosen as isotropic material. The plate has been modeled to take the form of the bone surface and the finite element method has been used for numerical analysis. The effect of stress on bones and implants has been examined for 1% healing by changing the plate length, plate width and plate material. RESULTS: It has been observed that the increase in plate length decreases cortical bone stress until a specific length. On the other hand, the increase in plate width has increased the stress on the bone. CONCLUSIONS: It is important to form the appropriate plate surface to the bone surface in terms of compliance with the bones.
dc.identifier.doi10.3233/BME-181012
dc.identifier.endpage628
dc.identifier.issn0959-2989
dc.identifier.issn1878-3619
dc.identifier.issue5
dc.identifier.pmid30400075
dc.identifier.scopus2-s2.0-85056089026
dc.identifier.scopusqualityQ3
dc.identifier.startpage611
dc.identifier.urihttps://doi.org/10.3233/BME-181012
dc.identifier.urihttps://hdl.handle.net/11508/49005
dc.identifier.volume29
dc.identifier.wosWOS:000462707700005
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherIos Press
dc.relation.ispartofBio-Medical Materials and Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectInternal fixation
dc.subjectimplant
dc.subjectfinite element analysis
dc.subjectcrack
dc.subjecttibia
dc.titleStatic and dynamic analyses of fracture fixation bone-plate systems for different plate materials and dimensions
dc.typeArticle

Dosyalar