Evaluation of compatibility of file and gutta-percha cones in three different endodontic systems using scanning electron microscopy

dc.contributor.authorEskibağlar, Mehmet
dc.contributor.authorÖzata, Merve Yeniçeri
dc.contributor.authorOcak, Mevlüt Sinan
dc.contributor.authorÖztekin, Faruk
dc.date.accessioned2026-08-12T16:07:47Z
dc.date.issued2023
dc.departmentFırat Üniversitesi
dc.description.abstractPurpose: The aim of this study was to evaluate the matching properties of the gutta-percha (GP) cones and different file systems with variable tapers. Methods: Fifteen files and GP cones TruNatomy Prime (TRN-P), WaveOne Gold Primary (WOG-P), and Reciproc Blue (Rec-B R25) systems were examined under a scanning electron microscope. Diameter measurements of files and GP cones were made from D1 to D16 using AutoCAD software. Data were analyzed with independent samples t-tests. Statistical significance was determined as p< 0.05. Results: The diameters of the file and GP cones were within the acceptable tolerance range. The file diameter was larger than the GP diameter at all points of incompatibility in the TRN-P system (p< 0.05). In the WOG-P group, the file diameter was wider up to the D10 level, while the GP cone diameter was wider at the D11 point and beyond p<0.05. In the Rec-B group, the file diameter was wider up to the D6 level, while the GP cone diameter was wider at the D7 point and beyond p<0.05. Conclusion: Three file systems are largely incompatible with the GP cones. In the TRN file system, unlike the other two groups, the GP cone had a narrower diameter than the file at each point. © 2023 Turkish Endodontic Society.
dc.identifier.doi10.14744/TEJ.2023.19483
dc.identifier.endpage19
dc.identifier.issn2459-1726
dc.identifier.issue1
dc.identifier.scopus2-s2.0-105026766351
dc.identifier.scopusqualityN/A
dc.identifier.startpage15
dc.identifier.trdizinid1239686
dc.identifier.urihttps://doi.org/10.14744/TEJ.2023.19483
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1239686
dc.identifier.urihttps://hdl.handle.net/11508/40895
dc.identifier.volume8
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherTurkish Endodontic Society
dc.relation.ispartofTurkish Endodontic Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_Scopus_20260511
dc.subjectDiameter; reciproc blue; rotary file systems; standardization; TruNatomy; WaveOne Gold
dc.titleEvaluation of compatibility of file and gutta-percha cones in three different endodontic systems using scanning electron microscopy
dc.typeArticle

Dosyalar