Stripping/flocculation/membrane bioreactor/reverse osmosis treatment of municipal landfill leachate

dc.contributor.authorHasar, Halil
dc.contributor.authorUnsal, Sezahat A.
dc.contributor.authorIpek, Ubeyde
dc.contributor.authorKaratas, Serdar
dc.contributor.authorCinar, Ozer
dc.contributor.authorYaman, Cevat
dc.contributor.authorKinaci, Cumali
dc.date.accessioned2026-08-12T17:45:47Z
dc.date.issued2009
dc.departmentFırat Üniversitesi
dc.description.abstractThis study presents a configuration for the complete treatment of landfill leachate with high organic and ammonium concentrations. Ammonia stripping is performed to overcome the ammonia toxicity to aerobic microorganisms. By coagulation-flocculation process, COD and suspended solids (SS) were removed 36 and 46%, respectively. After pretreatment, an aerobic/anoxic membrane bioreactor (Aer/An MBR) accomplished the COD and total inorganic nitrogen (total-N-i) removals above 90 and 92%, respectively, at SRT of 30 days. Concentrations of COD and total-N-i (not considering organic nitrogen) in the Aer/An MBR effluent decreased to 450 and 40 mg/l, respectively, by significant organic oxidation and nitrification/denitrification processes. As an advanced treatment for the leachate, the reverse osmosis (RO) was applied to the collected Aer/An MBR effluents. Reverse osmosis provided high quality effluent by reducing the effluent COD from MBR to less than 4.0 mg/l at SRT of 30 days. (C) 2009 Published by Elsevier B.V.
dc.description.sponsorshipScientific and Technical Research Council of Turkey (TUBITAK) [105Y345]
dc.description.sponsorshipWe would like to thank the Scientific and Technical Research Council of Turkey (TUBITAK) for supporting the study under project number of 105Y345. We would also like to convey our gratitude for supplied membranes to Zena Membranes Company, The Czech Republic.
dc.identifier.doi10.1016/j.jhazmat.2009.06.003
dc.identifier.endpage317
dc.identifier.issn0304-3894
dc.identifier.issn1873-3336
dc.identifier.issue1.Mar
dc.identifier.orcid0000-0002-3023-0734
dc.identifier.orcid0000-0001-8207-8669
dc.identifier.orcid0000-0003-1775-3466
dc.identifier.pmid19559524
dc.identifier.scopus2-s2.0-70349243177
dc.identifier.scopusqualityQ1
dc.identifier.startpage309
dc.identifier.urihttps://doi.org/10.1016/j.jhazmat.2009.06.003
dc.identifier.urihttps://hdl.handle.net/11508/60832
dc.identifier.volume171
dc.identifier.wosWOS:000271165100038
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofJournal of Hazardous Materials
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectLeachate
dc.subjectAmmonia toxicity
dc.subjectPretreatment
dc.subjectAerobic/anoxic MBR
dc.subjectReverse osmosis
dc.titleStripping/flocculation/membrane bioreactor/reverse osmosis treatment of municipal landfill leachate
dc.typeArticle

Dosyalar