Diffusion-weighted MR imaging of thyroid nodules

dc.contributor.authorBozgeyik, Zulkif
dc.contributor.authorCoskun, Sonay
dc.contributor.authorDagli, A. Ferda
dc.contributor.authorOzkan, Yusuf
dc.contributor.authorSahpaz, Fatih
dc.contributor.authorOgur, Erkin
dc.date.accessioned2026-08-12T17:30:09Z
dc.date.issued2009
dc.departmentFırat Üniversitesi
dc.description.abstractIntroduction The purpose of our study was to determine the diagnostic role of diffusion-weighted imaging (DWI) in the differentiating of malignant and benign thyroid nodules by using fine needle aspiration biopsy cytology criteria as a reference standard. The apparent diffusion coefficient (ADC) values of the normal-looking thyroid parenchyma were also evaluated both in normal patients and in patients with nodules. Methods Between March 2007 and February 2008, 76 consecutive patients with ultrasound-diagnosed thyroid nodules and 20 healthy subjects underwent diffusion-weighted MR imaging by using single-shot spin echo, echo planar imaging. A total of 93 nodules were included in the study using the following b factors 100, 200, and 300 mm(2)/s. ADC values of thyroid nodules and normal area in all subjects were calculated and compared using suitable statistical analysis. Results Mean ADC values for malignant and benign nodules were 0: 96 +/- 0: 65 X 10(-3) and 3.06 +/- 0.71 X 10(-3) mm(2) / s for b-100 factor, 0.56 +/- 0.43 X 10(-3) and 1.80 +/- 0.60 X 10(-3) mm(2) / s for b-200, and 0.30 +/- 0.20 X 10(-3) and 1.15 +/- 0.43 X 10(-3) mm(2) / s, for b-300, respectively. Mean ADC values of malignant nodules were lower than benign nodules. There were significant differences in ADC values between benign and malignant nodules. ADC values among normal-appearing thyroid parenchyma of patients and normal-appearing thyroid parenchyma of healthy subjects were insignificant at all b factors. Conclusion Benign nodules have higher ADC values than malignant ones. DWI may be helpful in differentiating malign and benign thyroid nodules.
dc.identifier.doi10.1007/s00234-008-0494-3
dc.identifier.endpage198
dc.identifier.issn0028-3940
dc.identifier.issue3
dc.identifier.pmid19165474
dc.identifier.scopus2-s2.0-60449101699
dc.identifier.scopusqualityQ1
dc.identifier.startpage193
dc.identifier.urihttps://doi.org/10.1007/s00234-008-0494-3
dc.identifier.urihttps://hdl.handle.net/11508/55981
dc.identifier.volume51
dc.identifier.wosWOS:000263419400008
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofNeuroradiology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260511
dc.subjectDiffusion-weighted MR imaging
dc.subjectDWI
dc.subjectThyroid nodule
dc.subjectFine needle aspiration biopsy
dc.titleDiffusion-weighted MR imaging of thyroid nodules
dc.typeArticle

Dosyalar