Effect of brushing on the surface properties of modified polyetheretherketone (PEEK)
| dc.contributor.author | Yildiz, Semsettin | |
| dc.contributor.author | Tekin, Bahar | |
| dc.date.accessioned | 2026-08-12T16:10:54Z | |
| dc.date.issued | 2025 | |
| dc.department | Fırat Üniversitesi | |
| dc.description.abstract | Purpose: To evaluate the surface roughness (SR) and surface topography (ST) of mechanical brushing with pure-unfilled PEEK (U-PEEK) and PEEK materials with different contents [titanium-containing PEEK (T-PEEK), ceramic-modified PEEK (C-PEEK) and glass fiber-reinforced PEEK (G-PEEK). Methods: A total of 40 disc-shaped samples (10 mm × 2 mm) were obtained (n= 10) from each group (U-PEEK, T-PEEK, C-PEEK, G-PEEK). After sanding and polishing, a profilometer was used to analyze all discs' surface roughness (Ra). Qualitative analysis (QA) was performed on random samples with the help of a scanning electron microscope (SEM). Brushing was done with a custom-made brushing simulator, and the analyses were repeated. Statistical analysis was performed (P< 0.05). Results: A statistically significant difference was found between the PEEK groups before and after brushing (P< 0.05). In the measurements before and after brushing, the lowest measurement value was seen in the C-PEEK and T-PEEK groups. While there was no significant difference between T-PEEK and C-PEEK measurements, both measurements found the highest measurement value in the G-PEEK group. In addition, in all groups, the average roughness values after brushing were statistically significantly higher than those before brushing. All groups except G-PEEK are below the clinically acceptable SR value (0.2 ?m) before and after brushing. T-PEEK and C-PEEK show better SR values. © 2025 Mosher and Linder, Inc. All rights reserved. | |
| dc.identifier.endpage | 32 | |
| dc.identifier.issn | 0894-8275 | |
| dc.identifier.issue | 1 | |
| dc.identifier.pmid | 40000004 | |
| dc.identifier.scopus | 2-s2.0-86000000319 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 27 | |
| dc.identifier.uri | https://hdl.handle.net/11508/42192 | |
| dc.identifier.volume | 38 | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Mosher and Linder, Inc | |
| dc.relation.ispartof | American Journal of Dentistry | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_Scopus_20260511 | |
| dc.subject | Benzophenones; Ceramics; Dental Materials; Glass; Humans; Ketones; Materials Testing; Microscopy, Electron, Scanning; Polyethylene Glycols; Polymers; Surface Properties; Titanium; Toothbrushing; benzophenone derivative; dental material; glass; glass fiber; ketone; macrogol derivative; polyetheretherketone; polymer; titanium; ceramics; chemistry; devices; human; materials testing; scanning electron microscopy; surface property; tooth brushing | |
| dc.title | Effect of brushing on the surface properties of modified polyetheretherketone (PEEK) | |
| dc.type | Article |