Experimental investigation on oxygenation efficiency of an effective aeration system for ponds

dc.contributor.authorKelestemur, Guluzar Tuna
dc.contributor.authorAytac, Ayca
dc.contributor.authorTuna, M. Cihat
dc.date.accessioned2026-08-12T17:38:58Z
dc.date.issued2024
dc.departmentFırat Üniversitesi
dc.description.abstractDissolved oxygen (DO) concentration in water is one of the most important water quality parameters in rivers, lakes, and reservoirs. The most effective way to increase DO concentration in water is aeration. Conduits with high aeration performance are predicted to significantly increase aeration efficiency. Based on this prediction, the physical parameters affecting the aeration efficiency (E 20) of the conduit aeration system were experimentally investigated. The effect of different jet plunge angles, flow rates, hydrostatic levels, Froude numbers, and gate opening rates was investigated to optimize the system for the best ventilation efficiency. As a result, the aeration efficiency (E 20) improves with increasing air intake performance at low gate openings, high Froude numbers, and hydrostatic levels. The increase in jet plunge angles and hydrostatic level directly increases the aeration efficiency. The study showed that conduit systems can be an important alternative for pond aeration due to initial investment and operating costs, low energy cost, and high aeration efficiency.
dc.description.sponsorshipDogus University
dc.description.sponsorshipNo Statement Available
dc.identifier.doi10.1007/s10499-024-01583-4
dc.identifier.endpage8647
dc.identifier.issn0967-6120
dc.identifier.issn1573-143X
dc.identifier.issue6
dc.identifier.orcid0000-0002-2108-6363
dc.identifier.orcid0000-0001-8581-4385
dc.identifier.orcid0000-0001-9005-1968
dc.identifier.scopus2-s2.0-85195860992
dc.identifier.scopusqualityQ2
dc.identifier.startpage8631
dc.identifier.urihttps://doi.org/10.1007/s10499-024-01583-4
dc.identifier.urihttps://hdl.handle.net/11508/58651
dc.identifier.volume32
dc.identifier.wosWOS:001252186200005
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofAquaculture International
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260511
dc.subjectAeration efficiency
dc.subjectAquaculture
dc.subjectPond aeration conduit
dc.titleExperimental investigation on oxygenation efficiency of an effective aeration system for ponds
dc.typeArticle

Dosyalar