Reliability of the Lactate Scout point-of-care instrument for the determination of blood L-lactate concentration in sheep
| dc.contributor.author | Kaynar, Ozgur | |
| dc.contributor.author | Karapinar, Tolga | |
| dc.contributor.author | Hayirli, Armagan | |
| dc.contributor.author | Baydar, Ersoy | |
| dc.date.accessioned | 2026-08-12T17:16:47Z | |
| dc.date.issued | 2015 | |
| dc.department | Fırat Üniversitesi | |
| dc.description.abstract | Background: Data on accuracy and precision of the Lactate Scout point-of-care (POC) analyzer in ovine medicine are lacking. Objective: The purpose of the study was to assess the reliability of the Lactate Scout in sheep. Materials and Methods: Fifty-seven sheep at varying ages with various diseases were included. Blood lactate concentration in samples collected from the jugular vein was measured immediately on the Lactate Scout. Plasma L-lactate concentration was measured by the Cobas autoanalyzer as the reference method. Data were subjected to Student's t-test, Passing-Bablok regression, and Bland-Altman plot analyses for comparison and assessment of accuracy, precision, and reliability. Results: Plasma L-lactate concentration was consistently lower than blood L-lactate concentration (3.06 +/- 0.24 vs 3.3 +/- 0.3 mmol/L, P < .0001). There was a positive correlation between plasma and blood L-lactate concentrations (r = .98, P < .0001). The Lactate Scout had 99% accuracy and 98% precision with the reference method. Blood (Y) and plasma (X) L-lactate concentrations were fitted to Y = 0.28 + 1.00 . X, with a residual standard deviation of 0.31 and a negligible deviation from the identity line (P = .93). The bias was fitted to Y = 0.10 + 0.05 . X, with Sy.x of 0.44 (P < .07). Conclusions: The Lactate Scout has high accuracy and precision, with a negligible bias. It is a reliable POC analyzer to assess L-lactate concentration in ovine medicine. | |
| dc.identifier.doi | 10.1111/vcp.12288 | |
| dc.identifier.endpage | 563 | |
| dc.identifier.issn | 0275-6382 | |
| dc.identifier.issn | 1939-165X | |
| dc.identifier.issue | 4 | |
| dc.identifier.pmid | 26348369 | |
| dc.identifier.scopus | 2-s2.0-84957434949 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 559 | |
| dc.identifier.uri | https://doi.org/10.1111/vcp.12288 | |
| dc.identifier.uri | https://hdl.handle.net/11508/52421 | |
| dc.identifier.volume | 44 | |
| dc.identifier.wos | WOS:000368418900014 | |
| dc.identifier.wosquality | Q3 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Wiley-Blackwell | |
| dc.relation.ispartof | Veterinary Clinical Pathology | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WoS_20260511 | |
| dc.subject | Accuracy | |
| dc.subject | bias | |
| dc.subject | lactate meter | |
| dc.subject | precision | |
| dc.subject | ovine medicine | |
| dc.title | Reliability of the Lactate Scout point-of-care instrument for the determination of blood L-lactate concentration in sheep | |
| dc.type | Article |







